A Comprehensive Analysis of Short-Circuit Current Behavior in PMSM Interturn Short-Circuit Faults
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
This paper presents a detailed analysis of short-circuit current behavior during interturn short-circuit faults in permanent magnet synchronous machines (PMSMs) by considering the short-circuit contact resistance. For this purpose, an finite element analysis (FEA)-based equivalent circuit model is developed to understand the circulating current behavior in the shorted turns. Various fault resistance and number of shorted turn combinations are examined at different torque and speed levels. To include saturation due to high fault currents, the inductance matrix of faulty machine is created in FEA environment and incorporated into the equivalent circuit model as four-dimensional lookup tables. In order to take loop responses into account, the model is controlled through field oriented control (FOC) with closed speed and current loops. An experimental setup is built to verify the simulation results using a PMSM with several winding taps. It is shown that the experimental results and the simulations are quite consistent with each other. The findings from this study are essential to predict fault severity, develop mitigation techniques and determine the safe operating area for faulty machines.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177 · cited 1×
“Due to the high short-circuit currents, the thermal effect becomes a critical factor, thus a transient thermal model of interturn short-circuit machine is proposed in [12].”
Background
Cited by
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Gurusamy, V., Bostanci, E., Li, C., Qi, Y., & Akin, B. (2021) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2020.3013128 · Cited by 93
“The PMSM was modeled through 2-D-FEA-based equivalent circuit model proposed in [22].”
MethodSelf-citationFault-Tolerant Control of PMSM With Inter-Turn Short-Circuit Fault
Zhang, J., Zhan, W., & Ehsani, M. (2019) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2019.2936225 · Cited by 64
“The physical structure of inter-turn SC fault can be found in [4], [5].”
Background
Metadata
- Authors
- Qi, Y., Bostanci, E., Gurusamy, V., & Akin, B.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2018-12
- Volume
- 33
- Issue
- 12
- Pages
- 10784-10793
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W2788037565
- Cited by
- 128
- References
- 1
- FWCI
- 3.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.