Impedance Circuit Model of Grid-Forming Inverter: Visualizing Control Algorithms as Circuit Elements
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
The impedance model is widely used for analyzing power converters. However, the output impedance is an external representation of a converter system, i.e., it compresses the entire dynamics into a single transfer function with internal details of the interaction between states hidden. As a result, there are no programmatic routines to link each control parameter to the system dynamic modes and to show the interactions among them, which makes the designers rely on their experience and heuristic to interpret the impedance model and its implications. To overcome these obstacles, this article proposes a new modeling tool named as impedance circuit model, visualizing the closed-loop power converter as an impedance circuit with discrete circuit elements rather than an all-in-one impedance transfer function. It can reveal the virtual impedance essence of all control parameters at different impedance locations and/or within different frequency bandwidths, and show their interactions and coupling effects. A grid-forming voltage source inverter is investigated as an example, with considering its voltage controller, current controller, control delay, voltage/current dq-frame cross-decoupling terms, output-voltage/current feedforward control, droop controllers, and three typical virtual impedances. The proposed modeling tool is validated by frequency-domain spectrum measurement and time-domain step response in simulations and experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 2×
“V OLTAGE source inverters (VSIs) are increasing in penetration in the world’s major power systems due to the rapid growth of renewable resources on the pathway toward decarbonization [1], [2].”
BackgroundMethodControl of Power Converters in AC Microgrids
Rocabert, J., Luna, A., Blaabjerg, F., & Rodríguez, P. (2012) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2199334 · Cited by 3,723 · cited 2×
“Voltage source inverters (VSIs) are increasing in penetration in the world’s major power systems due to the rapid growth of renewable resources on the pathway towards decarbonization [1], [2].”
BackgroundSynchronverters: Inverters That Mimic Synchronous Generators
Zhong, Q.-C., & Weiss, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2048839 · Cited by 3,107 · cited 1×
“Such a trend gives rise to a structural change as VSIs are starting to take over the dominant role from synchronous generators, which introduces new dynamic behavior and thereby poses new challenges to power system stability [3], [4].”
BackgroundModeling, Analysis and Testing of Autonomous Operation of an Inverter-Based Microgrid
Pogaku, N., Prodanovic, M., & Green, T. C. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.890003 · Cited by 3,018 · cited 1×
“It is worth mentioning that discussions given in this paragraph the state-space-based analysis in [6].”
BackgroundSelf-citationImpedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Harmonic Stability in Power Electronic-Based Power Systems: Concept, Modeling, and Analysis
Wang, X., & Blaabjerg, F. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2812712 · Cited by 1,282 · cited 2×
“It is worth mentioning that the complex-vector model in this article is distinguished from the conventional sequence model [24], [25].”
BackgroundMethodOutput Impedance Design of Parallel-Connected UPS Inverters With Wireless Load-Sharing Control
Guerrero, J. M., GarciadeVicuna, L., Matas, J., Castilla, M., & Miret, J. (2005) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2005.851634 · Cited by 1,221
Cited by
Revisiting Grid-Forming and Grid-Following Inverters: A Duality Theory
Li, Y., Gu, Y., & Green, T. C. (2022) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2022.3151851 · Cited by 686
Self-citationRavanji, M. H., Rathnayake, D. B., Mansour, M. Z., & Bahrani, B. (2023) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2023.3246566 · Cited by 47
“In [49], current feedforward terms are modeled using the impedance circuit modeling technique to visualize these terms as circuit elements.”
MethodGuruwacharya, N., Chakraborty, S., Saraswat, G., Bryce, R., Hansen, T. M., & Tonkoski, R. (2024) · IEEE Access · doi:10.1109/access.2024.3383323 · Cited by 34
“They achieve synchronization with the rest of the grid using frequency droop control (typically P − ω droop), similar to traditional synchronous generators [9], [10], [11].”
Background
Metadata
- Authors
- Li, Y., Gu, Y., Zhu, Y., Junyent-Ferre, A., Xiang, X., & Green, T. C.
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2021-03
- Volume
- 36
- Issue
- 3
- Pages
- 3377-3395
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W3048197658
- Cited by
- 207
- References
- 30
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.