A Fast and Accurate Loss Model of Converter-Fed Induction Motor in Central Air-Conditioning System
The DOI matches its Crossref record; the references it cites are not checked yet.
Abstract
In the traditional optimization model of central air-conditioner, the loss model of converter-fed motor is very rough, resulting in a large amount of energy waste. In this paper, a new energy loss model of central air-conditioning system from power to client is proposed. In the establishment of the loss model, the characteristics of pump load and variable frequency speed regulation are fully considered, and the electromagnetic variables which are difficult to be collected are replaced by the motor speed which can be directly calculated, so that the motor loss model can be introduced into the optimization model of the central air-conditioning system. A 5.5 kW converter-fed induction motor is tested under different speeds and loads, and the two-dimensional (2-D) loss data were obtained. Then, one-dimensional data were extracted from the measured 2-D data combined with the load characteristics of the pump, and compared with the calculated values of the proposed model in this article. The results show that the proposed loss model is of good accuracy and versatility. Because the proposed analytical model only needs the variable of motor speed to accurately estimate the losses, it can be easily applied to the optimization of central air-conditioning system.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the current construction of the Energy Internet, IoT technology is an important part, as shown in Figure 9 [75].”
From Reform of Electrical Engineering Undergraduate Teaching and the Curriculum System in the Context of the Energy Internet (2023) · cites this paper as [75]
Citations
The citation lists are queued
They are fetched later and appear here then.
References 39 · Cited by 8
Research works printed but not linked: 1
- Wang, 2009, Power Electronics
Metadata
- Authors
- Yi, J., Li, C., Zhang, D., Li, X., Jiang, M., Zhao, H., Zhang, Y., & Wu, X.
- Affiliations
- Guangxi University (CN)
- North China Electric Power University (CN)
- Shenyang University of Technology (CN)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2023-03
- Volume
- 38
- Issue
- 3
- Pages
- 3689-3699
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W4312219055
- Cited by
- 8
- References
- 39
- Citations by year
- 2026: 1 · 2025: 3 · 2024: 1 · 2023: 3
- FWCI
- 0.48
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- National Natural Science Foundation of China (5210071288)
- National Key Research and Development Program of China (2019YFE0118000)
- Guangxi Key Research and Development Program of China (2021AA11008)
- Guangxi Science and Technology Base and Talent Special Project of China (2021AC19120)
- Key Laboratory of Special Machine and High Voltage Apparatus Shenyang University of Technology
- Ministry of Education, China (KFKT202006)
- Innovation Project of Guangxi Graduate Education (YCBZ2022023)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Energy › Renewable Energy, Sustainability and the Environment › Energy Efficiency and Management
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power Systems and Control
- Keywords
- energy loss model, central air conditioning, variable frequency speed control, energy optimization, energy waste reduction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Fast and Accurate Loss Model of Converter-Fed Induction Motor in Central Air-Conditioning System. https://app.cochat.ai/papers/10.1109/tpel.2022.3222605
- The paper
- Yi, J., Li, C., Zhang, D., Li, X., Jiang, M., Zhao, H., Zhang, Y., & Wu, X. (2023). A Fast and Accurate Loss Model of Converter-Fed Induction Motor in Central Air-Conditioning System. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2022.3222605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.