A Robust Adjustable Speed Drive to Operate in Polluted Grid Conditions With Improved Line Current Harmonics
The DOI matches its Crossref record; 16 of the 16 references it cites were found in a registry or an index.
Abstract
Based on field power-quality data, distortion in supply voltage is found to be the dominant disturbance followed by unbalance. A compensation module is introduced to protect the ASD from grid disturbances; while reducing stress on the dc-bus capacitor, it also mitigates the harmonics in the source current of the ASD. The proposed topology is analyzed by simulations and validated by a lab test setup.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Transformer and Inductor Design Handbook
McLyman, C. W. T. (2004) · CRC Press eBooks · doi:10.1201/9780203913598 · Cited by 1,369
Wang, H., Chung, H. S.-H., & Liu, W. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2262057 · Cited by 220
Harmonic Analysis of Grid Connected Power Electronic Systems in Low Voltage Distribution Networks
Kumar, D., & Zare, F. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2454537 · Cited by 159
Self-citationEffect of supply voltage harmonics on the input current of single-phase diode bridge rectifier loads
Mansoor, A., Grady, W. M., Thallam, R. S., et al. (1995) · IEEE Transactions on Power Delivery · doi:10.1109/61.400924 · Cited by 154
Multiobjective Dynamic Voltage Restorer With Modified EPLL Control and Optimized PI-Controller Gains
Naidu, T. A., Arya, S. R., & Maurya, R. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2837009 · Cited by 71
Suh, Y., Go, Y.-R., & Rho, D. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2126015 · Cited by 58
Rendusara, D., Çengelci, E., Enjeti, P. N., et al. (1999) · doi:10.1109/apec.1999.750457 · Cited by 44
The impact of grid unbalances on the reliability of DC-link capacitors in a motor drive
Wang, H., Davari, P., Kumar, D., et al. (2017) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2017.8096748 · Cited by 34
Self-citationGopalan, S., Vasudevan, K., Kumar, D., et al. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2991133 · Cited by 22
Self-citationVoltage Unbalance: Impact of Various Definitions on Severity Assessment for Adjustable Speed Drives
Gopalan, S., Vasudevan, K., Kumar, D., et al. (2018) · IEEE India International Conference on Power Electronics · doi:10.1109/iicpe.2018.8709478 · Cited by 16
Self-citation
Research works printed but not linked: 2
- Yializis, 2019, A disruptive dc-link capacitor technology for use in electric drive inverters, 102
- 2002, IEC Electromagnetic Compatibility (EMC) 61000 - Part 2-4:EnvironmentCompatibility Levels in Industrial Plants for Low-Frequency Conducted Disturbances
Metadata
- Authors
- Gopalan, S., Vasudevan, K., & Kumar, D.
- Affiliations
- Danfoss Drives, Chennai, India
- Indian Institute of Technology Madras (IN)
- Danfoss (Denmark) (DK)
- Venue
- IEEE Transactions on Power Electronics
- Published
- 2025-04
- Volume
- 40
- Issue
- 4
- Pages
- 5823-5834
- ISSN
- 0885-8993 (ISSN-L)
- 1941-0107
- OpenAlex
- W4405614718
- Cited by
- 0
- References
- 16
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Electronics (publishedVersion)
- Funders
- Ministry of Human Resource Development
- Department of Science and Technology
- Danfoss Drives India
- UAY programme
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
- Keywords
- adjustable speed drives, power quality, supply voltage distortion, voltage unbalance, harmonic compensation, line current harmonics, retrofitting
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Robust Adjustable Speed Drive to Operate in Polluted Grid Conditions With Improved Line Current Harmonics. https://app.cochat.ai/papers/10.1109/tpel.2024.3519858
- The paper
- Gopalan, S., Vasudevan, K., & Kumar, D. (2025). A Robust Adjustable Speed Drive to Operate in Polluted Grid Conditions With Improved Line Current Harmonics. IEEE Transactions on Power Electronics. https://doi.org/10.1109/tpel.2024.3519858
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.