The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Folded Waveguide Traveling-Wave Tube Sources for Terahertz Radiation
Open accessAbstract
Microfabricated folded waveguide traveling-wave tubes (TWTs) are potential compact sources of wide-band, high-power terahertz radiation. We present feasibility studies of an oscillator concept using an amplifier with delayed feedback. Simulations of a 560-GHz oscillator and experimental evaluation of the concept at 50 GHz are presented. Additionally, results from various fabrication methods that are under investigation, such as X-ray lithography, electroforming, and molding (LIGA), UV LIGA, and deep reactive ion etching are presented. Observations and measurements are reported on the generation of stable single-frequency oscillation states. On varying the feedback level, the oscillation changes from a stable single-frequency state at the threshold to multifrequency spectra in the overdriven state. Simulation and experimental results on amplifier characterization and dynamics of the regenerative TWT oscillator include spectral evolution and phase stability of the generated frequencies. The results of the experiment are in good agreement with the simulations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Siegel, P. H. (2002) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/22.989974 · Cited by 3,045
Time-frequency signal analysis
Boashash, B. (1993) · Medical Entomology and Zoology · Cited by 465
Time-Frequency Signal Analysis: Methods and Applications.
Boashash, B. (1993) · Biometrics · doi:10.2307/2532288 · Cited by 320
(2001) · Springer eBooks · doi:10.1007/978-94-010-0824-2 · Cited by 149
Reduced interference distributions: biological applications and interpretations
Williams, W. J. (1996) · Proceedings of the IEEE · doi:10.1109/5.535245 · Cited by 92
Cited by
Vacuum Electronic High Power Terahertz Sources
Booske, J. H., Dobbs, R. J., Joye, C. D., Kory, C. L., Neil, G. R., Park, G.-S., Park, J., & Temkin, R. J. (2011) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2011.2151610 · Cited by 1,086
Self-citationBooske, J. H. (2008) · Physics of Plasmas · doi:10.1063/1.2838240 · Cited by 635
Self-citationLewis, R. A. (2014) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/47/37/374001 · Cited by 470
From Terahertz Imaging to Terahertz Wireless Communications
Huang, Y., Shen, Y., & Wang, J. (2023) · Engineering · doi:10.1016/j.eng.2022.06.023 · Cited by 312
Lai, K., Ma, T., Bo, X., Anlage, S., & Shvets, G. (2016) · Scientific Reports · doi:10.1038/srep28453 · Cited by 70
Metadata
- Authors
- Bhattacharjee, S., Booske, J. H., Kory, C. L., van der Weide, D. W., Limbach, S., Gallagher, S., Welter, J. D., Lopez, M. R., Gilgenbach, R. M., Ives, R. L., Read, M. E., Divan, R., & Mancini, D. C.
- Venue
- IEEE Transactions on Plasma Science
- Published
- 2004-06
- Volume
- 32
- Issue
- 3
- Pages
- 1002-1014
- ISSN
- 0093-3813 (ISSN-L)
- OpenAlex
- W2148114668
- Cited by
- 266
- References
- 5
- FWCI
- 4.50
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Folded Waveguide Traveling-Wave Tube Sources for Terahertz Radiation. https://app.cochat.ai/papers/10.1109/tps.2004.828886
- The paper
- Bhattacharjee, S., Booske, J. H., Kory, C. L., van der Weide, D. W., Limbach, S., Gallagher, S., Welter, J. D., Lopez, M. R., Gilgenbach, R. M., Ives, R. L., Read, M. E., Divan, R., & Mancini, D. C. (2004). Folded Waveguide Traveling-Wave Tube Sources for Terahertz Radiation. IEEE Transactions on Plasma Science. https://doi.org/10.1109/tps.2004.828886
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.