Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 175

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Fault Location on a Transmission Line Using Synchronized Voltage Measurements

Brahma, S.M., Girgis, A.A. · 2004 · IEEE Transactions on Power Delivery

Abstract

Many methods for fault location using synchronized phasor measurement have been reported in literature. Most of these methods use voltage and current measurements at one or both ends of a transmission line. Accuracy of current measurement is limited by the accuracy of the current transformers (CT) used. This paper describes a fault-location method for transmission lines using only synchronized voltage measurements at both ends of the line, eliminating the inherent error due to CT. The method can be applied to transposed and untransposed lines. The method is tested using results from a steady state fault-analysis program and EMTP.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2003.822532

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 175

Metadata

Authors
Brahma, S. M., & Girgis, A. A.
Venue
IEEE Transactions on Power Delivery
Published
2004-10
Volume
19
Issue
4
Pages
1619-1622
ISSN
0885-8977 (ISSN-L)
OpenAlex
W2117826692
Cited by
175
References
1
FWCI
9.28
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Fault Location on a Transmission Line Using Synchronized Voltage Measurements. https://app.cochat.ai/papers/10.1109/tpwrd.2003.822532
The paper
Brahma, S. M., & Girgis, A. A. (2004). Fault Location on a Transmission Line Using Synchronized Voltage Measurements. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2003.822532

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.