The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
An Islanding Detection Method for Distributed Generations Using Voltage Unbalance and Total Harmonic Distortion of Current
Abstract
Distributed generation (DG) units are rapidly increasing and most of them are interconnected with distribution network to supply power into the network as well as local loads. Islanding operations of DG usually occur when power supply from the main utility is interrupted due to several reasons but the DG keeps supplying power into the distribution networks. These kinds of islanding conditions cause negative impacts on protection, operation, and management of distribution systems; therefore, it is necessary to effectively detect the islanding conditions and swiftly disconnect DG from distribution network. Generally, if there are large changes in loading for DG after loss of the main power supply, then islanding conditions are easily detected by monitoring several parameters: voltage magnitude, phase displacement, and frequency change. However, in case of small changes in loading for DG, the conventional methods have some difficulty in detecting such a particular islanding condition. This paper presents a new islanding detection algorithm for DG effectively working in the most of DG loading conditions. This paper proposes two new parameters for detecting islanding operation of DG: voltage unbalance and total harmonic distortion of current. The proposed method effectively combines the conventional parameters with the newly proposed parameters for detecting the islanding conditions. The proposed methods were verified using the radial distribution network of IEEE 34 bus.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power electronics: circuits, devices, and applications
(1989) · Choice Reviews Online · doi:10.5860/choice.26-3292 · Cited by 2,282
Radial distribution test feeders
Kersting, W. H. (1991) · IEEE Transactions on Power Systems · doi:10.1109/59.119237 · Cited by 1,888
Determining the impact of distributed generation on power systems. I. Radial distribution systems
Barker, P. P., & De Mello, R. W. (2002) · 2000 Power Engineering Society Summer Meeting (Cat. No.00CH37134) · doi:10.1109/pess.2000.868775 · Cited by 1,208
Cited by
Support Vector Machine-Based Islanding and Grid Fault Detection in Active Distribution Networks
Baghaee, H. R., Mlakic, D., Nikolovski, S., & Dragicevic, T. (2020) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2916621 · Cited by 235
Postigo Marcos, F., Mateo Domingo, C., Gómez San Román, T., Palmintier, B., Hodge, B.-M., Krishnan, V., De Cuadra García, F., & Mather, B. (2017) · Energies · doi:10.3390/en10111896 · Cited by 106
Metadata
- Authors
- Jang, S.-I., & Kim, K.-H.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2004-04
- Volume
- 19
- Issue
- 2
- Pages
- 745-752
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W2132499494
- Cited by
- 592
- References
- 3
- FWCI
- 9.81
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Islanding Detection Method for Distributed Generations Using Voltage Unbalance and Total Harmonic Distortion of Current. https://app.cochat.ai/papers/10.1109/tpwrd.2003.822964
- The paper
- Jang, S.-I., & Kim, K.-H. (2004). An Islanding Detection Method for Distributed Generations Using Voltage Unbalance and Total Harmonic Distortion of Current. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2003.822964
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.