The DOI matches its Crossref record.
Dynamic Thermal Modelling of Power Transformers
Open accessAbstract
The aim of this paper is to introduce hot-spot and top-oil temperature thermal models for more accurate temperature calculations during transient states based on data received in a normal heat run test (i.e., the top oil in the tank of the transformer and the average winding-to-average oil gradient). Oil viscosity changes and loss variation with temperature are taken into account. The new thermal models will be validated using experimental (fiber-optic test) results obtained at varying load current on a 250-MVA-ONAF-cooled unit, a 400-MVA-ONAF-cooled unit and a 605-MVA-OFAF-cooled unit. The results are also compared with the IEEE-Loading guide (1995) Annex G method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
At the feeder level, uneven spatial distribution of EV chargers aggravates voltage drop and phase imbalance.
“At the feeder level, the additional problem of uneven spatial distribution of EV chargers aggravates the voltage drop and phase imbalance problem [129].”
From Economic Impacts and Mitigation for the Grid Connected Electric Vehicle Charging: A Technical and Operational Overview (2026) · cites this paper as [129]
The supplied passages and searches for EV chargers, feeder voltage drop, and phase imbalance found only discussion of transformer thermal modelling and loading (section 2 and section 4.1.2; page numbers unavailable). No passage in our copy addresses whether uneven charger placement aggravates feeder voltage drop or phase imbalance. (LLM, conf=0.76)
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 11
- 10.3403/00325978 · DOI
- 10.1109/ieeestd.2003.94283 · DOI
- Incropera, 1996, Fundamentals of Heat and Mass Transfer
- Karsai, 1987, Large Power Transformers
- 10.1109/TPWRD.2002.807747 · DOI
- 10.1109/TPWRD.2003.817516 · DOI
- 10.1109/61.141852 · DOI
- 10.1109/28.273636 · DOI
- 10.1109/61.915478 · DOI
- 10.1109/61.915479 · DOI
- Lampe, Hot-spot measurements in power transformers
Cited by
Sorted by citations
Ikhajangbe, O. E., Dhulipati, H., & Liu, S. (2026) · IEEE Access · doi:10.1109/access.2026.3684508 · Cited by 5
Metadata
- Authors
- Susa, D., Lehtonen, M., & Nordman, H.
- Affiliations
- Aalto University (FI)
- ABB (Finland) (FI)
- ORCID
- Lehtonen, M.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2005-01
- Volume
- 20
- Issue
- 1
- Pages
- 197-204
- ISSN
- 0885-8977 (ISSN-L)
- OpenAlex
- W1980641210
- Cited by
- 351
- References
- 0
- Citations by year
- 2026: 16 · 2025: 15 · 2024: 27 · 2023: 21 · 2022: 24 · 2021: 20 · 2020: 26 · 2019: 25 · 2018: 15 · 2017: 26 · 2016: 17 · 2015: 12 · 2014: 9 · 2013: 16 · 2012: 27
- FWCI
- 6.65
- Type
- journal article
- Language
- en
- Open access
- green
- aaltodoc.aalto.fi
- Locations
- IEEE Transactions on Power Delivery (publishedVersion)
- Aaltodoc (Aalto University) (submittedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Transformer Diagnostics and Insulation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Thermal Analysis in Power Transmission
- Physical Sciences › Materials Science › Electronic, Optical and Magnetic Materials › Magnetic Properties and Applications
- Keywords
- power transformers, hot spot temperature, top oil temperature, transient thermal analysis, oil viscosity, fiber optic temperature measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review