The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
A Control Methodology and Characterization of Dynamics for a Photovoltaic (PV) System Interfaced With a Distribution Network
Abstract
This paper proposes a control strategy for a single-stage, three-phase, photovoltaic (PV) system that is connected to a distribution network. The control is based on an inner current-control loop and an outer DC-link voltage regulator. The current-control mechanism decouples the PV system dynamics from those of the network and the loads. The DC-link voltage-control scheme enables control and maximization of the real power output. Proper feedforward actions are proposed for the current-control loop to make its dynamics independent of those of the rest of the system. Further, a feedforward compensation mechanism is proposed for the DC-link voltage-control loop, to make the PV system dynamics immune to the PV array nonlinear characteristic. This, in turn, permits the design and optimization of the PV system controllers for a wide range of operating conditions. A modal/sensitivity analysis is also conducted on a linearized model of the overall system, to characterize dynamic properties of the system, to evaluate robustness of the controllers, and to identify the nature of interactions between the PV system and the network/loads. The results of the modal analysis confirm that under the proposed control strategy, dynamics of the PV system are decoupled from those of the distribution network and, therefore, the PV system does not destabilize the distribution network. It is also shown that the PV system dynamics are not influenced by those of the network (i.e., the PV system maintains its stability and dynamic properties despite major variations in the line length, lineX/Rratio, load type, and load distance from the PV system).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425
Power-Electronic Systems for the Grid Integration of Renewable Energy Sources: A Survey
Carrasco, J. M., Franquelo, L. G., Bialasiewicz, J. T., Galvan, E., PortilloGuisado, R. C., Prats, M. A. M., Leon, J. I., & Moreno-Alfonso, N. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.878356 · Cited by 4,018
A Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621
Maximum photovoltaic power tracking: an algorithm for rapidly changing atmospheric conditions
Hussein, K. H. (1995) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:19951577 · Cited by 1,764
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Vector analysis and control of advanced static VAR compensators
Schauder, C., & Mehta, H. (1993) · IEE Proceedings C Generation, Transmission and Distribution · doi:10.1049/ip-c.1993.0044 · Cited by 1,049
Enslin, J. H. R., & Heskes, P. J. M. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.836615 · Cited by 824
Distributed Power Generation Planning And Evaluation
Willis, H. L., & Scott, W. G. (2000) · Medical Entomology and Zoology · Cited by 489
Voltage Fluctuations on Distribution Level Introduced by Photovoltaic Systems
Woyte, A., Thong, V. V., Belmans, R., & Nijs, J. (2006) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2005.845454 · Cited by 482
Impact of widespread photovoltaics generation on distribution systems
Thomson, M., & Infield, D. G. (2007) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20060009 · Cited by 350 · cited 1×
“The majority of this body of the literature has focused on single-phase PV systems, with an emphasis on their harmonic interactions with the distribution networks [15]–[17] and on their impact on the power quality (PQ) [18]–[20].”
BackgroundEffects of PV Grid-Connected System Location on a Distribution System
Srisaen, N., & Sangswang, A. (2006) · IEEE Asia Pacific Conference on Circuits and Systems (APCCAS) · doi:10.1109/apccas.2006.342175 · Cited by 80
Cited by
Control Techniques in AC, DC, and Hybrid AC–DC Microgrid: A Review
Sahoo, S. K., Sinha, A. K., & Kishore, N. K. (2018) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2786588 · Cited by 534
Metadata
- Authors
- Yazdani, A., & Dash, P. P.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2009-07
- Volume
- 24
- Issue
- 3
- Pages
- 1538-1551
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2158794090
- Cited by
- 332
- References
- 13
- FWCI
- 7.48
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.