Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 193

The DOI matches its Crossref record.

Bidirectional, High-Power DC Transformer

Jovcic, Dragan·2009·IEEE Transactions on Power Delivery

Abstract

This paper studies a bidirectional dc-dc converter concept which is capable of achieving very high stepping ratios with MW level power transfers. The converter can find potential application in connecting high-power dc sources, interfacing to high-voltage dc transmission or to flexible ac transmission system elements. The converter is based on two resonant circuits which share a common ac capacitor. The topology is simple and utilizes thyristors with potentially all soft switchings. Complete analytical modelling is presented which enables systematic design procedure for the converter. The detailed digital simulation on PSCAD platform confirms satisfactory operation on a 5-MW test system, which connects 4-kV dc source to an 80-kV high voltage dc grid. The converter shows good responses to rapid changes in power magnitude/direction and it is concluded that robustness to terminal voltage disturbances is excellent. Since the highest-power phase-control thyristors are employed, the converter can potentially be used at much higher power levels. The passive components are of reasonable size.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2009.2028600

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 193

Metadata

Authors
Jovcic, D.
Venue
IEEE Transactions on Power Delivery
Published
2009-10
Volume
24
Issue
4
Pages
2276-2283
ISSN
  • 0885-8977 (ISSN-L)
  • 1937-4208
OpenAlex
W2074012173
Cited by
193
References
0
FWCI
4.49
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Bidirectional, High-Power DC Transformer. https://app.cochat.ai/papers/10.1109/tpwrd.2009.2028600
The paper
Jovcic, D. (2009). Bidirectional, High-Power DC Transformer. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2009.2028600

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.