The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
A Survey of Mobile Robots for Distribution Power Line Inspection
Abstract
The purpose of this paper is to present the most important achievements in the field of distribution power line inspection by mobile robots. Stimulated by the need for fast, accurate, safe and low-cost power line inspection, which would increase the quality of power delivery, the field of automated power line inspection has witnessed rapid development over the last decade. This paper addresses automated helicopter inspection, inspection with flying robots and inspection with climbing robots. The first attempts to automate power line inspection were conducted in the field of helicopter inspection. In recent years, however, the research was mostly focused on flying and climbing robots. These two types of robots for automated power line inspection are critically assessed according to four important characteristics: design requirements, inspection quality, autonomy and universality of inspection. Besides, some general not yet identified problems and tasks of inspection robots, which should be addressed in the future, are presented. In conclusion, the two robot types have specific benefits and drawbacks so that none can currently be considered generally advantageous.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An overview of the condition monitoring of overhead lines
Aggarwal, R. K., Johns, A. T., Jayasinghe, J. A. S. B., & Su, W. (2000) · Electric Power Systems Research · doi:10.1016/s0378-7796(99)00037-1 · Cited by 134
Visual control of an unmanned aerial vehicle for power line inspection
Golightly, I., & Jones, D. B. (2005) · International Conference on Advanced Robotics (ICAR) · doi:10.1109/.2005.1507426 · Cited by 109
Aerial video inspection of overhead power lines
Whitworth, C. C., Jones, D. I., Duller, A. W. G., & Earp, G. K. (2001) · Power Engineering Journal · doi:10.1049/pe:20010103 · Cited by 100
Corner detection and matching for visual tracking during power line inspection
Golightly, I., & Jones, D. B. (2003) · Image and Vision Computing · doi:10.1016/s0262-8856(03)00097-0 · Cited by 89
Power line inspection - a UAV concept
Jones, D. R. H. (2005) · doi:10.1049/ic:20050472 · Cited by 76
Early jump-out corner detectors
Cooper, J., Venkatesh, S., & Kitchen, L. (1993) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/34.236246 · Cited by 69
Cited by
Nguyen, V. N., Jenssen, R., & Roverso, D. (2018) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2017.12.016 · Cited by 591
Remote sensing methods for power line corridor surveys
Matikainen, L., Lehtomäki, M., Ahokas, E., Hyyppä, J., Karjalainen, M., Jaakkola, A., Kukko, A., & Heinonen, T. (2016) · ISPRS Journal of Photogrammetry and Remote Sensing · doi:10.1016/j.isprsjprs.2016.04.011 · Cited by 410
Power transmission line inspection robots: A review, trends and challenges for future research
Alhassan, A. B., Zhang, X., Shen, H., & Xu, H. (2020) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2020.105862 · Cited by 337
Fault Detection in Power Equipment via an Unmanned Aerial System Using Multi Modal Data
Jalil, B., Leone, G. R., Martinelli, M., Moroni, D., Pascali, M. A., & Berton, A. (2019) · Sensors · doi:10.3390/s19133014 · Cited by 141
UAV Visual and Thermographic Power Line Detection Using Deep Learning
Santos, T., Cunha, T., Dias, A., Moreira, A. P., & Almeida, J. (2024) · Sensors · doi:10.3390/s24175678 · Cited by 39
Metadata
- Authors
- Katrasnik, J., Pernus, F., & Likar, B.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2010-01
- Volume
- 25
- Issue
- 1
- Pages
- 485-493
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2065039610
- Cited by
- 312
- References
- 6
- FWCI
- 6.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Survey of Mobile Robots for Distribution Power Line Inspection. https://app.cochat.ai/papers/10.1109/tpwrd.2009.2035427
- The paper
- Katrasnik, J., Pernus, F., & Likar, B. (2010). A Survey of Mobile Robots for Distribution Power Line Inspection. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2009.2035427
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.