The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Path Characteristic Frequency-Based Fault Locating in Radial Distribution Systems Using Wavelets and Neural Networks
Abstract
This paper proposes a new algorithm for localizing phase to ground faults in an electric power distribution system. Fault-originated traveling waves propagate along the distribution paths in both directions away from the fault point and are reflected at line terminations, junctions between feeders, laterals, and the fault location. Depending on the paths which traveling waves reciprocate through, the transient signal at each node contains certain path characteristic frequencies (PCFs). Energy spectrum of the transient signal has high density around the path characteristic frequencies. On this basis, the transient voltage is decomposed by a wavelet filter and its energy spectrum is decomposed into different levels. Depending on the bandwidth of the wavelet filter and the path characteristic frequencies, the decomposed signal in each level contains a certain percentage of energy. Then, a neural network-based methodology is proposed as a power distribution line fault locator. Energy percentage in each level is the candidate feature for training the artificial neural network. Simulations and the training process for the neural network are performed respectively using ATP/EMTP and MATLAB. It is shown that the results of the proposed algorithm are quite satisfactory.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Development of a New Type Fault Locator Using the One-Terminal Voltage and Current Data
Takagi, T., Yamakoshi, Y., Yamaura, M., Kondow, R., & Matsushima, T. (1982) · IEEE Transactions on Power Apparatus and Systems · doi:10.1109/tpas.1982.317615 · Cited by 635 · cited 1×
“Several fault-locating methods have been proposed based on various techniques of power frequency wave analysis [1]–[8] and travelling wave theory [9]–[19].”
Method
Cited by
Zidan, A., Khairalla, M., Abdrabou, A. M., Khalifa, T., Shaban, K., Abdrabou, A., El Shatshat, R., & Gaouda, A. M. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2517620 · Cited by 274
A Comparative Review of Fault Location/Identification Methods in Distribution Networks
Haleem, A. M. I., Sharma, M., Sajan, K. S., & Babu, K. N. D. (2018) · 2018 1st International Conference on Advanced Research in Engineering Sciences (ARES) · doi:10.1109/aresx.2018.8723300 · Cited by 14
Metadata
- Authors
- Pourahmadi-Nakhli, M., & Safavi, A. A.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2011-04
- Volume
- 26
- Issue
- 2
- Pages
- 772-781
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2100175349
- Cited by
- 158
- References
- 1
- FWCI
- 12.75
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Path Characteristic Frequency-Based Fault Locating in Radial Distribution Systems Using Wavelets and Neural Networks. https://app.cochat.ai/papers/10.1109/tpwrd.2010.2050218
- The paper
- Pourahmadi-Nakhli, M., & Safavi, A. A. (2011). Path Characteristic Frequency-Based Fault Locating in Radial Distribution Systems Using Wavelets and Neural Networks. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2010.2050218
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.