The DOI matches its Crossref record.
Optimal Distributed Generation Allocation and Sizing in Distribution Systems via Artificial Bee Colony Algorithm
Abstract
Distributed generation (DG) has been utilized in some electric power networks. Power loss reduction, environmental friendliness, voltage improvement, postponement of system upgrading, and increasing reliability are some advantages of DG-unit application. This paper presents a new optimization approach that employs an artificial bee colony (ABC) algorithm to determine the optimal DG-unit's size, power factor, and location in order to minimize the total system real power loss. The ABC algorithm is a new metaheuristic, population-based optimization technique inspired by the intelligent foraging behavior of the honeybee swarm. To reveal the validity of the ABC algorithm, sample radial distribution feeder systems are examined with different test cases. Furthermore, the results obtained by the proposed ABC algorithm are compared with those attained via other methods. The outcomes verify that the ABC algorithm is efficient, robust, and capable of handling mixed integer nonlinear optimization problems. The ABC algorithm has only two parameters to be tuned. Therefore, the updating of the two parameters towards the most effective values has a higher likelihood of success than in other competing metaheuristic methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Liu, C., Chau, K. T., Wu, D., & Gao, S. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2271951 · Cited by 917
Das, C. K., Bass, O., Kothapalli, G., Mahmoud, T. S., & Habibi, D. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.068 · Cited by 656
Abdmouleh, Z., Gastli, A., Ben-Brahim, L., Haouari, M., & Al-Emadi, N. A. (2017) · Renewable Energy · doi:10.1016/j.renene.2017.05.087 · Cited by 508
Keane, A., Ochoa, L. F., Borges, C. L. T., Ault, G. W., Alarcon-Rodriguez, A. D., Currie, R. A. F., Pilo, F., Dent, C., & Harrison, G. P. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2214406 · Cited by 429
Mahmud, N., & Zahedi, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.030 · Cited by 377
Ant Lion Optimization Algorithm for optimal location and sizing of renewable distributed generations
Ali, E. S., Abd Elazim, S. M., & Abdelaziz, A. Y. (2017) · Renewable Energy · doi:10.1016/j.renene.2016.09.023 · Cited by 366
Pesaran H.A, M., Huy, P. D., & Ramachandaramurthy, V. K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.10.071 · Cited by 351
Optimal sizing and siting techniques for distributed generation in distribution systems: A review
Prakash, P., & Khatod, D. K. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.12.099 · Cited by 329
Devabalaji, K. R., & Ravi, K. (2016) · Ain Shams Engineering Journal · doi:10.1016/j.asej.2015.07.002 · Cited by 290
Gopiya Naik, S., Khatod, D. K., & Sharma, M. P. (2013) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2013.06.008 · Cited by 288
Zubo, R. H. A., Mokryani, G., Rajamani, H.-S., Aghaei, J., Niknam, T., & Pillai, P. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.10.036 · Cited by 218
Radosavljevic, J., Arsic, N., Milovanovic, M., & Ktena, A. (2020) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2019.000259 · Cited by 122
Optimal allocation, sizing of PHEV parking lots in distribution system
El-Zonkoly, A., & dos Santos Coelho, L. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2014.12.026 · Cited by 92
Metadata
- Authors
- Abu-Mouti, F. S., & El-Hawary, M. E.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2011-10
- Volume
- 26
- Issue
- 4
- Pages
- 2090-2101
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2161362625
- Cited by
- 725
- References
- 0
- FWCI
- 26.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.