The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Suppressing DC Voltage Ripples of MMC-HVDC Under Unbalanced Grid Conditions
Abstract
There are second-order harmonics in the dc voltage and current when the MMC-HVDC system is under unbalanced grid conditions, even if the negative-sequence current controller is employed. This paper presents a supplementary dc voltage ripple suppressing controller (DCVRSC) to eliminate the second-order harmonic in the dc voltage of the MMC-HVDC system. The instantaneous power of the converter arm and phase unit indicates that there are zero-sequence double-line frequency components in the three-phase unit voltages when the ac system is under an unbalanced fault. Since the zero-sequence components cannot be offset by each other, they lead to the second-order harmonic in the dc voltage and dc current. The DCVRSC is developed to compensate the zero-sequence components in three-phase unit voltages. Simulation results based on a detailed PSCAD/EMTDC model prove that the DCVRSC can eliminate the second-order harmonic in the dc voltage. Meanwhile, the ac currents are kept balanced under the unbalanced fault conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tu, Q., Xu, Z., & Xu, L. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2011.2115258 · Cited by 1,387
Self-citation
Cited by
Operation, Control, and Applications of the Modular Multilevel Converter: A Review
Debnath, S., Qin, J., Bahrani, B., Saeedifard, M., & Barbosa, P. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2309937 · Cited by 2,210
Dekka, A., Wu, B., Fuentes, R. L., Perez, M., & Zargari, N. R. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2742938 · Cited by 576
Analysis and Control of Modular Multilevel Converters With Integrated Battery Energy Storage
Vasiladiotis, M., & Rufer, A. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2303297 · Cited by 402
Li, S., Wang, X., Yao, Z., Li, T., & Peng, Z. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2329059 · Cited by 343
Zhang, M., Huang, L., Yao, W., & Lu, Z. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2269140 · Cited by 292
Metadata
- Authors
- Tu, Q., Xu, Z., Chang, Y., & Guan, L.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2012-07
- Volume
- 27
- Issue
- 3
- Pages
- 1332-1338
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2004165606
- Cited by
- 236
- References
- 1
- FWCI
- 14.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Suppressing DC Voltage Ripples of MMC-HVDC Under Unbalanced Grid Conditions. https://app.cochat.ai/papers/10.1109/tpwrd.2012.2196804
- The paper
- Tu, Q., Xu, Z., Chang, Y., & Guan, L. (2012). Suppressing DC Voltage Ripples of MMC-HVDC Under Unbalanced Grid Conditions. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2012.2196804
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.