The DOI matches its Crossref record.
Benefits of Distribution-Level Power Electronics for Supporting Distributed Generation Growth
Abstract
It is expected that distribution networks will be required to accommodate large amounts of distributed generation (DG). Keeping power flows and voltages within their limits will require either traditional infrastructure upgrades or active compensation. The form of active compensation (e.g., series, shunt, back to back, multiterminal), quantity, and rating of the compensator should be chosen to realize the best cost-benefit ratio. Distributed-generator and compensator placement algorithms are used with a power-flow and constraint satisfaction algorithm to analyze a large number of case studies (using real U.K. network data). From these cases, assessments of compensator performance are made and summarized statistically. When considering incremental deployment across all networks, with the site of greatest benefit chosen at each increment, it is found that static synchronous compensators provide the most favorable cost-benefit ratio. In contrast, multiterminal voltage-source converters tend to provide the greatest flexibility when considering uniform deployment across all networks. It is also observed that traditional reinforcement enhances the benefits provided by active compensation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Li, P., Ji, H., Wang, C., Zhao, J., Song, G., Ding, F., & Wu, J. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2017.2686009 · Cited by 447
Haque, M. M., & Wolfs, P. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.04.025 · Cited by 331
Benefits analysis of Soft Open Points for electrical distribution network operation
Cao, W., Wu, J., Jenkins, N., Wang, C., & Green, T. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.12.022 · Cited by 303
Self-citationOperating principle of Soft Open Points for electrical distribution network operation
Cao, W., Wu, J., Jenkins, N., Wang, C., & Green, T. (2016) · Applied Energy · doi:10.1016/j.apenergy.2015.12.005 · Cited by 300
Self-citationAn Overview of Soft Open Points in Electricity Distribution Networks
Jiang, X., Zhou, Y., Ming, W., Yang, P., & Wu, J. (2022) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2022.3148599 · Cited by 278
Ji, H., Wang, C., Li, P., Ding, F., & Wu, J. (2019) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2018.2833545 · Cited by 267
Metadata
- Authors
- Bloemink, J. M., & Green, T. C.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2013-04
- Volume
- 28
- Issue
- 2
- Pages
- 911-919
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2000158788
- Cited by
- 248
- References
- 0
- FWCI
- 6.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.