DC Fault Detection and Location in Meshed Multiterminal HVDC Systems Based on DC Reactor Voltage Change Rate
Abstract
The change rate of the dc reactor voltage with predefined protection voltage thresholds is proposed to provide fast and accurate dc fault detection in a meshed multiterminal HVDC system. This is equivalent to the measurement of the second derivative of the dc current but has better robustness in terms of electromagnetic-interference noise immunization. In addition to fast dc fault detection, the proposed scheme can also accurately discriminate the faulty branch from the healthy ones in a meshed dc network by considering the voltage polarities and amplitudes of the two dc reactors connected to the same converter dc terminal. Fast fault detection leads to lower fault current stresses on dc circuit breakers and converter equipment. The proposed method requires no telecommunication, is independent of power-flow direction, and is robust to fault resistance variation. Simulation of a meshed three-terminal HVDC system demonstrates the effectiveness of the proposed dc fault detection scheme.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Design and Operation of a Hybrid Modular Multilevel Converter
Zeng, R., Xu, L., Yao, L., & Williams, B. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2320822 · Cited by 455
Self-citation
Metadata
- Authors
- Li, R., Xu, L., & Yao, L.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2017-06
- Volume
- 32
- Issue
- 3
- Pages
- 1516-1526
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2467290497
- Cited by
- 350
- References
- 1
- FWCI
- 15.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: DC Fault Detection and Location in Meshed Multiterminal HVDC Systems Based on DC Reactor Voltage Change Rate. https://app.cochat.ai/papers/10.1109/tpwrd.2016.2590501
- The paper
- Li, R., Xu, L., & Yao, L. (2017). DC Fault Detection and Location in Meshed Multiterminal HVDC Systems Based on DC Reactor Voltage Change Rate. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2016.2590501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.