Abstract
Resonance and harmonic phenomena can occur when HVDC and Flexible Alternating Current Transmission System devices are inserted into ac grids. Frequency response analysis and electromagnetic transient (EMT) type simulations of converter stations are essential for analyzing and preventing negative effects. This paper presents two approaches for deriving the high frequency response of a converter station: using simplified analytical representation and accurate EMT-type model. Validations with control parameter impacts are presented. This paper also presents a test case, based on a recent HVdc project, where potential resonances can occur between the converter station and its ac network. It is demonstrated analytically that these resonances are mainly due to control system parameters and ac network configurations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Shair, J., Li, H., Hu, J., & Xie, X. (2021) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2021.111111 · Cited by 433
Sequence Impedance Modeling of Modular Multilevel Converters
Sun, J., & Liu, H. (2017) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2017.2762408 · Cited by 287
Metadata
- Authors
- Saad, H., Fillion, Y., Deschanvres, S., Vernay, Y., & Dennetiere, S.
- Venue
- IEEE Transactions on Power Delivery
- Published
- 2017-06
- Volume
- 32
- Issue
- 3
- Pages
- 1565-1573
- ISSN
- 0885-8977 (ISSN-L)
- 1937-4208
- OpenAlex
- W2568867773
- Cited by
- 176
- References
- 0
- FWCI
- 6.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: On Resonances and Harmonics in HVDC-MMC Station Connected to AC Grid. https://app.cochat.ai/papers/10.1109/tpwrd.2017.2648887
- The paper
- Saad, H., Fillion, Y., Deschanvres, S., Vernay, Y., & Dennetiere, S. (2017). On Resonances and Harmonics in HVDC-MMC Station Connected to AC Grid. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2017.2648887
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.