CoChat

The DOI matches its Crossref record; 48 of the 48 references it cites were found in a registry or an index.

Intelligent Diagnosis of Incipient Fault in Power Distribution Lines Based on Corona Detection in UV-Visible Videos

Davari, Noushin, Akbarizadeh, Gholamreza, Mashhour, Elaheh · 2021 · IEEE Transactions on Power Delivery

Abstract

As one of the non-contact methods for incipient fault diagnosis of power distribution lines, UV-Visible imaging has become popular due to its good performance and robustness against environmental parameters. This paper presents a deep learning-based method for UV-Visible video processing. First, for preparing the dataset, some videos are acquired from distribution lines using CoroCam 6D2 considering observation distance, the imager's gain, air pressure, and humidity as effective parameters on the discharge area in the images. Then, based on the logged information of unplanned power outages in the system and also planned inspections over a year, the incipient fault type and the severity level of the incipient fault are determined for each video. For processing each video, frames are extracted with the rate according to the nominal voltage of the line. Power devices are detected in each frame using Faster R-CNN and are tracked through the whole video frames to compensate the camera movement. Then, color thresholding is used for each device to identify corona discharges in the frames. In-depth median filtering is also used through the video to eliminate noises in the UV channel. Finally, based on the ratio of the detected discharge area to the area of the equipment, the severity level of the incipient fault is determined. The proposed method not only performs better than the state-of-the-art but also is a practical method, and with the least dependence on environmental conditions, can automatically identify incipient faults in distribution lines, even in videos containing several possible defective devices.

Overview

Integrity signals

Registry

Crossref · 10.1109/tpwrd.2020.3046161

Cites

48 of 48 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 47 references

Research works printed but not linked: 1

  1. liu, 2018, Method for evaluating flashover state of insulator ultraviolet image based on sparse representation, Gaodianya Jishu/High Voltage Engineering, 44, 3352

Cited by

See all 106

Metadata

Authors
Davari, N., Akbarizadeh, G., & Mashhour, E.
Affiliations
Shahid Chamran University of Ahvaz (IR)
Venue
IEEE Transactions on Power Delivery
Published
2021-12
Volume
36
Issue
6
Pages
3640-3648
ISSN
  • 0885-8977 (ISSN-L)
  • 1937-4208
OpenAlex
W3115434540
Cited by
106
References
47
Citations by year
2026: 13 · 2025: 12 · 2024: 23 · 2023: 23 · 2022: 17 · 2021: 18
FWCI
7.13
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Power Delivery (publishedVersion)
Funders
  • Shahid Chamran University of Ahvaz
  • Khouzestan Electricity Power Distribution Company (SCU.EE99.269)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Power Line Inspection Robots
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › High voltage insulation and dielectric phenomena
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electrical Fault Detection and Protection
Keywords
incipient fault diagnosis, distribution lines, corona discharge detection, fault classification, video frame extraction, device tracking, color thresholding, median filter

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Intelligent Diagnosis of Incipient Fault in Power Distribution Lines Based on Corona Detection in UV-Visible Videos. https://app.cochat.ai/papers/10.1109/tpwrd.2020.3046161
The paper
Davari, N., Akbarizadeh, G., & Mashhour, E. (2021). Intelligent Diagnosis of Incipient Fault in Power Distribution Lines Based on Corona Detection in UV-Visible Videos. IEEE Transactions on Power Delivery. https://doi.org/10.1109/tpwrd.2020.3046161

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.