Convexity of the Set of Feasible Injections and Revenue Adequacy in FTR Markets
The DOI matches its Crossref record.
Abstract
The feasible set of power injections for the constrained power flow equations is nonconvex when practical transmission capacity and bus voltage limits are imposed. The projection onto the space of active power injections may be "close" to convex, but this is not sufficient to guarantee revenue adequacy for the settlement of financial transmission rights.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541
Convex Relaxation of Optimal Power Flow—Part II: Exactness
Low, S. H. (2014) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2014.2323634 · Cited by 523
A Survey of Relaxations and Approximations of the Power Flow Equations
Molzahn, D. K., & Hiskens, I. A. (2019) · Foundations and Trends® in Electric Energy Systems · doi:10.1561/3100000012 · Cited by 272
Self-citationExamining the limits of the application of semidefinite programming to power flow problems
Lesieutre, B. C., Molzahn, D. K., Borden, A. R., & DeMarco, C. L. (2011) · 2011 49th Annual Allerton Conference on Communication, Control, and Computing (Allerton) · doi:10.1109/allerton.2011.6120344 · Cited by 219
“It is generally nonconvex and may not be connected [2].”
BackgroundSelf-citationA Centrality Measure for Electrical Networks
Hines, P., & Blumsack, S. (2008) · Proceedings of the 41st Annual Hawaii International Conference on System Sciences (HICSS 2008) · doi:10.1109/hicss.2008.5 · Cited by 192
Sparsity-Exploiting Moment-Based Relaxations of the Optimal Power Flow Problem
Molzahn, D. K., & Hiskens, I. A. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2372478 · Cited by 162
“, the five- and nine-bus systems in [6] an d the five-bus system in [5]; see [20]–[22] for analysis of thes e and other small test cases) implies that similar phenomena can occur in large practical problems as well.”
BackgroundSelf-citationOptimal Power Flow Using Graph Neural Networks
Owerko, D., Gama, F., & Ribeiro, A. (2020) · ICASSP 2020 - 2020 IEEE International Conference on Acoustics, Speech and Signal Processing (ICASSP) · doi:10.1109/icassp40776.2020.9053140 · Cited by 160
Quadratically constrained quadratic programs on acyclic graphs with application to power flow
Bose, S., Gayme, D. F., Chandy, K. M., & Low, S. H. (2012) · arXiv · doi:10.48550/arxiv.1203.5599 · Cited by 131
Geometry of injection regions of power networks
Zhang, B., & Tse, D. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2208205 · Cited by 118
“Unfortunately, the injection region is not convex in genera l [12].”
Background(2009) · doi:10.1109/pes.2009.5275353 · Cited by 84
“Some existing reliability or market operation studies have approached the analysis of the power grid from a graphtheoretic or complex-systems perspective [ 16-20 ].”
Background
Metadata
- Authors
- Lesieutre, B. C., & Hiskens, I. A.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2005-11
- Volume
- 20
- Issue
- 4
- Pages
- 1790-1798
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2113921577
- Cited by
- 120
- References
- 0
- FWCI
- 4.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.