Load Frequency Control of an Isolated Small-Hydro Power Plant With Reduced Dump Load
The DOI matches its Crossref record.
Abstract
In this paper, a novel technique for load frequency control of an isolated small-hydro plant is presented. In general, the frequency is controlled by using a dump load, whose rating is equal to the rated power output of the plant. The new scheme proposed reduces the size of the dump load by controlling input power of the hydro power plant using on/off controls. The water flowing through the penstock is rerouted in smaller pipes, two or three fitted with motor operated valves. The opening or closing of the valves is achieved by on/off controls. The on/off control linearly raises or lowers the generation. A generalized transfer function model for the system is developed with an on/off control logic. Finally, the transient performance of the system is compared for the two-pipe case (50% dump load) and the three-pipe case (30% dump load)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
“In [14], a frequency response model of electric power systems consisting of hydro power plants is well-described.”
BackgroundIntegration of Renewable Energy into Present and Future Energy Systems
Sims, R., Mercado, P., Krewitt, W., Bhuyan, G., Flynn, D., Holttinen, H., Jannuzzi, G., Khennas, S., Liu, Y., Nilsson, L. J., et al. (2011) · Renewable Energy Sources and Climate Change Mitigation · doi:10.1017/cbo9781139151153.012 · Cited by 98
A review of control techniques for inverter-based distributed energy resources applications
Hasheminasab, S., Alzayed, M., & Chaoui, H. (2024) · Energies · doi:10.3390/en17122940 · Cited by 56
Metadata
- Authors
- Doolla, S., & Bhatti, T. S.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2006-11
- Volume
- 21
- Issue
- 4
- Pages
- 1912-1919
- ISSN
- 0885-8950 (ISSN-L)
- OpenAlex
- W2117375092
- Cited by
- 112
- References
- 0
- FWCI
- 0.00
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.