Optimization of Pumped Storage Capacity in an Isolated Power System With Large Renewable Penetration
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
This work describes an economic analysis of the inclusion of pumped storage in a small island system that has abundant renewable energy available but that at times cannot accept all of this power because of limits imposed by security criteria. The question of whether or how much pumped storage to include is addressed by formulating a linear programming optimization problem. The stochastic nature of load and renewable production is addressed using scenarios developed through fuzzy clustering. Both the unit capacity in MW and the reservoir storage capacity in MWh are optimized, and optimal operating strategies for the scenarios are produced.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Energy Storage and Its Use With Intermittent Renewable Energy
Barton, J. P., & Infield, D. G. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2003.822305 · Cited by 1,388
Operation and sizing of energy storage for wind power plants in a market system
Korpaas, M., Holen, A. T., & Hildrum, R. (2003) · International Journal of Electrical Power & Energy Systems · doi:10.1016/s0142-0615(03)00016-4 · Cited by 502
Optimal operation and hydro storage sizing of a wind–hydro power plant
Castronuovo, E. D., & Lopes, J. P. (2004) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2004.08.002 · Cited by 220
Executive overview: energy storage options for a sustainable energy future
Schainker, R. B. (2005) · IEEE Power Engineering Society General Meeting, 2004. · doi:10.1109/pes.2004.1373298 · Cited by 179
Leonhard, W., & Grobe, E. M. (2004) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2004.1373049 · Cited by 47
Evaluation of integration of pumped storage units in an isolated network
Brown, P. (2006) · doi:10.34626/cdvy-re08 · Cited by 5
Self-citation
Cited by
A review of energy storage technologies for wind power applications
Díaz-González, F., Sumper, A., Gomis-Bellmunt, O., & Villafáfila-Robles, R. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.01.029 · Cited by 1,547
Pumped hydro energy storage system: a technological review
Rehman, S., Al-Hadhrami, L. M., & Alam, M. M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.12.040 · Cited by 1,264
“[86] optimized the size of pumps and reservoirs for maximum exploitation of the wind potential of an island, using a linear programming method.”
MethodEnergy storage for mitigating the variability of renewable electricity sources: An updated review
Beaudin, M., Zareipour, H., Schellenberglabe, A., & Rosehart, W. (2010) · Energy for Sustainable Development · doi:10.1016/j.esd.2010.09.007 · Cited by 1,042
Robust Unit Commitment With Wind Power and Pumped Storage Hydro
Jiang, R., Wang, J., & Guan, Y. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2011.2169817 · Cited by 941
Tan, K. M., Babu, T. S., Ramachandaramurthy, V. K., Kasinathan, P., Solanki, S. G., & Raveendran, S. K. (2021) · Journal of Energy Storage · doi:10.1016/j.est.2021.102591 · Cited by 776
Metadata
- Authors
- Brown, P. D., Peas Lopes, J. A., & Matos, M. A.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2008-05
- Volume
- 23
- Issue
- 2
- Pages
- 523-531
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2166824378
- Cited by
- 289
- References
- 6
- FWCI
- 10.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.