Dynamic Contribution of DFIG-Based Wind Plants to System Frequency Disturbances
The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
The paper investigates contribution of doubly fed induction generator (DFIG) to system frequency responses. Impact of different governor settings and system inertia are investigated. Three distinct cases are simulated in order to illustrate the influence of DFIG penetration on frequency regulation. Provision of inertial response by DFIG through artificial speed coupling is also presented. The effects of the inertial response on the machine behavior and its significance for frequency regulation are discussed. The influence of converter current limits and auxiliary loop parameters on the inertial response are illustrated and a novel control algorithm is developed for extracting maximum energy from the turbine in a stable manner. The results of the study are illustrated on the example of an isolated power system consisting of a diesel generator and a DFIG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
(2005) · Wiley eBooks · doi:10.1002/0470012684 · Cited by 2,915
Vector Control and Dynamics of AC Drives
Novotny, D. W., & Lipo, T. A. (1996) · doi:10.1093/oso/9780198564393.001.0001 · Cited by 1,841
Wind Turbines Emulating Inertia and Supporting Primary Frequency Control
Morren, J., de Haan, S. W. H., Kling, W. L., & Ferreira, J. A. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.861956 · Cited by 1,263
Frequency Control and Wind Turbine Technologies
Lalor, G., Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857393 · Cited by 698
Ekanayake, J., & Jenkins, N. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.827712 · Cited by 641
Frequency support from doubly fed induction generator wind turbines
Ramtharan, G., Jenkins, N., & Ekanayake, J. B. (2007) · IET Renewable Power Generation · doi:10.1049/iet-rpg:20060019 · Cited by 530
Inertial response of variable speed wind turbines
Morren, J., Pierik, J., & de Haan, S. W. H. (2006) · Electric Power Systems Research · doi:10.1016/j.epsr.2005.12.002 · Cited by 459
The Inertial Response of Induction-Machine-Based Wind Turbines
Mullane, A., & O'Malley, M. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.852081 · Cited by 309
Contribution of DFIG-based wind farms to power system short-term frequency regulation
Anaya‐Lara, O., Hughes, F. M., Jenkins, N., & Štrbac, G. (2006) · IEE Proceedings - Generation Transmission and Distribution · doi:10.1049/ip-gtd:20050264 · Cited by 133
Measurement-based estimation of wind farm inertia
Littler, T., Fox, B., & Flynn, D. (2005) · doi:10.1109/ptc.2005.4524432 · Cited by 35
Cited by
Definition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
The Relevance of Inertia in Power Systems
Tielens, P., & Van Hertem, D. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.016 · Cited by 809
“In [37, 38] for instance, a response proportional to the frequency (droop control) is proposed while in [39, 4] a step-response is evaluated.”
BackgroundDelille, G., Francois, B., & Malarange, G. (2012) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2205025 · Cited by 776
Overview of Control Systems for the Operation of DFIGs in Wind Energy Applications
Cardenas, R., Pena, R., Alepuz, S., & Asher, G. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2243372 · Cited by 670
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Overview of control systems for the operation of DFIGs in wind energy applications
Pena, R., Cardenas, R., & Asher, G. (2013) · IECON 2013 - 39th Annual Conference of the IEEE Industrial Electronics Society · doi:10.1109/iecon.2013.6699116 · Cited by 529
Inertia Emulation Control Strategy for VSC-HVDC Transmission Systems
Zhu, J., Booth, C. D., Adam, G. P., Roscoe, A. J., & Bright, C. G. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2213101 · Cited by 466
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
Gautam, D., Goel, L., Ayyanar, R., Vittal, V., & Harbour, T. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2051690 · Cited by 327
Mohseni, M., & Islam, S. M. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.039 · Cited by 327
Ye, H., Pei, W., & Qi, Z. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2490342 · Cited by 262
Wang, Y., Delille, G., Bayem, H., Guillaud, X., & Francois, B. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2240466 · Cited by 248
“First, only the rated operating point of Wind Farms (WF) has been simulated and analysed in a lot of published works, such as in [12], [14], [16], and [17].”
BackgroundZhao, J., Lyu, X., Fu, Y., Hu, X., & Li, F. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2016.2537539 · Cited by 209
“The influence of converter current limits and auxiliary loop parameters on inertia response under rated wind speed was analyzed in [14].”
BackgroundFang, J., Zhang, R., Li, H., & Tang, Y. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2871085 · Cited by 170
Frequency Control in Isolated/Islanded Microgrids Through Voltage Regulation
Farrokhabadi, M., Canizares, C. A., & Bhattacharya, K. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2479576 · Cited by 168
“In [21], a supplementary loop is introduced in the con-”
BackgroundFrequency support from modular multilevel converter based multi-terminal HVDC schemes
Adeuyi, O. D., Cheah-Mane, M., Liang, J., Jenkins, N., Wu, Y., Li, C., & Wu, X. (2015) · 2015 IEEE Power & Energy Society General Meeting · doi:10.1109/pesgm.2015.7286086 · Cited by 56
Metadata
- Authors
- Kayikci, M., & Milanovic, J. V.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2009-05
- Volume
- 24
- Issue
- 2
- Pages
- 859-867
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2129326263
- Cited by
- 462
- References
- 10
- FWCI
- 12.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.