Impact of Increased Penetration of DFIG-Based Wind Turbine Generators on Transient and Small Signal Stability of Power Systems
The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The targeted and current development of wind energy in various countries around the world reveals that wind power is the fastest growing power generation technology. Among the several wind generation technologies, variable speed wind turbines utilizing doubly fed induction generators (DFIGs) are gaining momentum in the power industry. With the increase in penetration of these wind turbines, the power system dominated by synchronous machines will experience a change in dynamics and operational characteristics. Given this assertion, the present paper develops an approach to analyze the impact of increased penetration of DFIG-based wind turbines on transient and small signal stability of a large power system. The primary basis of the method is to convert the DFIG machines into equivalent conventional round rotor synchronous machines and then evaluate the sensitivity of the eigenvalues with respect to inertia. In this regard, modes that are both detrimentally and beneficially affected by the change in inertia are identified. These modes are then excited by appropriate disturbances and the impact of reduced inertia on transient stability performance is also examined. The proposed technique is tested on a large test system representing the Midwestern portion of the U.S. interconnection. The results obtained indicate that the proposed method effectively identifies both detrimental and beneficial impacts of increased DFIG penetration both for transient stability and small signal stability related performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power System Stability and Control
Kundur, P. (1994) · Cited by 19,639
(2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825981 · Cited by 3,719
Grid Integration of Wind Energy Conversion Systems
Heier, S. (1998) · Cited by 1,619
Control of DFIG-Based Wind Generation for Power Network Support
Hughes, F. M., Anaya-Lara, O., Jenkins, N., & Strbac, G. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.857275 · Cited by 415
The impact of large scale wind power generation on power system oscillations
Slootweg, J. G., & Kling, W. L. (2003) · Electric Power Systems Research · doi:10.1016/s0378-7796(03)00089-0 · Cited by 392
Nunes, M. V. A., Lopes, J. P., Zurn, H. H., Bezerra, U. H., & de Almeida, R. G. (2004) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2004.832078 · Cited by 271
Effect of Variable Speed Wind Turbine Generator on Stability of a Weak Grid
Muljadi, E., Butterfield, C. P., Parsons, B., & Ellis, A. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.889602 · Cited by 250
Cited by
Definition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
Self-citationFoundations and Challenges of Low-Inertia Systems (Invited Paper)
Milano, F., Dörfler, F., Hug, G., Hill, D. J., & Verbič, G. (2018) · 2018 Power Systems Computation Conference (PSCC) · doi:10.23919/pscc.2018.8450880 · Cited by 1,039
The Relevance of Inertia in Power Systems
Tielens, P., & Van Hertem, D. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.016 · Cited by 809
“Also in the case of increased penetration of converter connected units which are not synchronously linked to the system and therefore do not participate in electromechanical oscillations, the modes of the system are influenced [44, 45, 46].”
BackgroundUnderstanding Small-Signal Stability of Low-Inertia Systems
Markovic, U., Stanojev, O., Aristidou, P., Vrettos, E., Callaway, D., & Hug, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2021.3061434 · Cited by 370
Gautam, D., Goel, L., Ayyanar, R., Vittal, V., & Harbour, T. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2051690 · Cited by 327
Self-citationMohseni, M., & Islam, S. M. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.03.039 · Cited by 327
Tamimi, B., Canizares, C., & Bhattacharya, K. (2013) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2012.2235151 · Cited by 324
O'Sullivan, J., Rogers, A., Flynn, D., Smith, P., Mullane, A., & O'Malley, M. (2014) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2316974 · Cited by 291
Impacts of Intermittent Renewables on Electricity Generation System Operation
Perez-Arriaga, I. J., & Batlle, C. (2012) · Economics of Energy & Environmental Policy · doi:10.5547/2160-5890.1.2.1 · Cited by 235
Pumped storage in systems with very high wind penetration
Tuohy, A., & O’Malley, M. (2011) · Energy Policy · doi:10.1016/j.enpol.2011.01.026 · Cited by 218
Robust Controller for DFIGs of Grid-Connected Wind Turbines
da Costa, J. P., Pinheiro, H., Degner, T., & Arnold, G. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2098630 · Cited by 182
Smart Generation and Transmission With Coherent, Real-Time Data
Bakken, D. E., Bose, A., Hauser, C. H., Whitehead, D. E., & Zweigle, G. C. (2011) · Proceedings of the IEEE · doi:10.1109/jproc.2011.2116110 · Cited by 177
“Evolving to a noncarbon-based electrical infrastructure will require integrating large amounts of nontraditional generation sources (such as wind and solar) that behave differently from existing generation (such as nuclear, coal, and natural gas) [4], [5].”
BackgroundWong, W. C., Chung, C. Y., Chan, K. W., & Chen, H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2254505 · Cited by 169
“However, DFIG affects the dynamic behavior of the systems [14].”
Background
Metadata
- Authors
- Gautam, D., Vittal, V., & Harbour, T.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2009-08
- Volume
- 24
- Issue
- 3
- Pages
- 1426-1434
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2141709135
- Cited by
- 680
- References
- 7
- FWCI
- 21.65
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.