The DOI matches its Crossref record.
Rotor Angle Instability Prediction Using Post-Disturbance Voltage Trajectories
Abstract
A new method for predicting the rotor angle stability status of a power system immediately after a large disturbance is presented. The proposed two-stage method involves estimation of the similarity of post-fault voltage trajectories of the generator buses after the disturbance to some pre-identified templates and then prediction of the stability status using a classifier which takes the similarity values calculated at the different generator buses as inputs. The typical bus voltage variation patterns after a disturbance for both stable and unstable situations are identified from a database of simulations using fuzzy C-means clustering algorithm. The same database is used to train a support vector machine classifier which takes proximity of the actual voltage variations to the identified templates as features. Development of the system and its performance were demonstrated using a case study carried out on the IEEE 39-bus system. Investigations showed that the proposed method can accurately predict the stability status six cycles after the clearance of a fault. Further, the robustness of the proposed method was examined by analyzing its performance in predicting the instability when the network configuration is altered.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gomez, F. R., Rajapakse, A. D., Annakkage, U. D., & Fernando, I. T. (2011) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2010.2082575 · Cited by 407
Self-citationIntelligent Time-Adaptive Transient Stability Assessment System
Yu, J. J. Q., Hill, D. J., Lam, A. Y. S., Gu, J., & Li, V. O. K. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2707501 · Cited by 370
A Review on Artificial Intelligence for Grid Stability Assessment
You, S., Zhao, Y., Mandich, M., Cui, Y., Li, H., Xiao, H., Fabus, S., Su, Y., Liu, Y., Yuan, H., et al. (2020) · 2020 IEEE International Conference on Communications, Control, and Computing Technologies for Smart Grids (SmartGridComm) · doi:10.1109/smartgridcomm47815.2020.9302990 · Cited by 70
Metadata
- Authors
- Rajapakse, A. D., Gomez, F., Nanayakkara, K., Crossley, P. A., & Terzija, V. V.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2010-05
- Volume
- 25
- Issue
- 2
- Pages
- 947-956
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2149111570
- Cited by
- 184
- References
- 0
- FWCI
- 7.23
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Rotor Angle Instability Prediction Using Post-Disturbance Voltage Trajectories. https://app.cochat.ai/papers/10.1109/tpwrs.2009.2036265
- The paper
- Rajapakse, A. D., Gomez, F., Nanayakkara, K., Crossley, P. A., & Terzija, V. V. (2010). Rotor Angle Instability Prediction Using Post-Disturbance Voltage Trajectories. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2009.2036265
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.