The DOI matches its Crossref record.
Enhanced Utilization of Voltage Control Resources With Distributed Generation
Open accessAbstract
Distributed generation (DG) is increasing in penetration on power systems across the world. In rural areas, voltage rise limits the permissible penetration levels of DG. Another increasingly important issue is the impact on transmission system voltages of DG reactive power demand. Here, a passive solution is proposed to reduce the impact on the transmission system voltages and overcome the distribution voltage rise barrier such that more DG can connect. The fixed power factors of the generators and the tap setting of the transmission transformer are determined by a linear programming formulation. The method is tested on a sample section of radial distribution network and on a model of the all island Irish transmission system illustrating that enhanced passive utilization of voltage control resources can deliver many of the benefits of active management without any of the expense or perceived risk, while also satisfying the conflicting objectives of the transmission system operator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of Challenges and Research Opportunities for Voltage Control in Smart Grids
Sun, H., Guo, Q., Qi, J., Ajjarapu, V., Bravo, R., Chow, J., Li, Z., Moghe, R., Nasr-Azadani, E., Tamrakar, U., et al. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2897948 · Cited by 496
Keane, A., Ochoa, L. F., Borges, C. L. T., Ault, G. W., Alarcon-Rodriguez, A. D., Currie, R. A. F., Pilo, F., Dent, C., & Harrison, G. P. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2214406 · Cited by 429
Self-citationOptimal planning of distributed generation systems in distribution system: A review
Viral, R., & Khatod, D. K. (2012) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.05.020 · Cited by 408
Mahmud, N., & Zahedi, A. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.030 · Cited by 377
An Optimal and Distributed Method for Voltage Regulation in Power Distribution Systems
Zhang, B., Lam, A. Y. S., Dominguez-Garcia, A. D., & Tse, D. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2347281 · Cited by 325
Metadata
- Authors
- Keane, A., Ochoa, L. F., Vittal, E., Dent, C. J., & Harrison, G. P.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2011-02
- Volume
- 26
- Issue
- 1
- Pages
- 252-260
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2135188150
- Cited by
- 200
- References
- 0
- FWCI
- 11.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Enhanced Utilization of Voltage Control Resources With Distributed Generation. https://app.cochat.ai/papers/10.1109/tpwrs.2009.2037635
- The paper
- Keane, A., Ochoa, L. F., Vittal, E., Dent, C. J., & Harrison, G. P. (2011). Enhanced Utilization of Voltage Control Resources With Distributed Generation. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2009.2037635
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.