Electric Load Forecasting Based on Statistical Robust Methods
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, the stochastic characteristics of the electric consumption in France are analyzed. It is shown that the load time series exhibit lasting abrupt changes in the stochastic pattern, termed breaks. The goal is to propose an efficient and robust load forecasting method for prediction up to a day-ahead. To this end, two new robust procedures for outlier identification and suppression are developed. They are termed the multivariate ratio-of-medians-based estimator (RME) and the multivariate minimum-Hellinger-distance-based estimator (MHDE). The performance of the proposed methods has been evaluated on the French electric load time series in terms of execution times, ability to detect and suppress outliers, and forecasting accuracy. Their performances are compared with those of the robust methods proposed in the literature to estimate the parameters of SARIMA models and of the multiplicative double seasonal exponential smoothing. A new robust version of the latter is proposed as well. It is found that the RME approach outperforms all the other methods for “normal days” and presents several interesting properties such as good robustness, fast execution, simplicity, and easy online implementation. Finally, to deal with heteroscedasticity, we propose a simple novel multivariate modeling that improves the quality of the forecast.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Statistics: The Approach Based on Influence Functions
Ruppert, D. (1987) · Technometrics · doi:10.2307/1269782 · Cited by 3,880
Cited by
Raza, M. Q., & Khosravi, A. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.04.065 · Cited by 1,021
On recent advances in PV output power forecast
Raza, M. Q., Nadarajah, M., & Ekanayake, C. (2016) · Solar Energy · doi:10.1016/j.solener.2016.06.073 · Cited by 544
Robust Estimation in Signal Processing: A Tutorial-Style Treatment of Fundamental Concepts
Zoubir, A. M., Koivunen, V., Chakhchoukh, Y., & Muma, M. (2012) · IEEE Signal Processing Magazine · doi:10.1109/msp.2012.2183773 · Cited by 411
Self-citationElectric load forecasting in smart grids using Long-Short-Term-Memory based Recurrent Neural Network
Zheng, J., Xu, C., Zhang, Z., & Li, X. (2017) · 2017 51st Annual Conference on Information Sciences and Systems (CISS) · doi:10.1109/ciss.2017.7926112 · Cited by 341
Robust Statistics for Signal Processing
Zoubir, A. M., Koivunen, V., Ollila, E., & Muma, M. (2018) · Cambridge University Press eBooks · doi:10.1017/9781139084291 · Cited by 239
Deep Learning-Based Interval State Estimation of AC Smart Grids Against Sparse Cyber Attacks
Wang, H., Ruan, J., Wang, G., Zhou, B., Liu, Y., Fu, X., & Peng, J. (2018) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2018.2804669 · Cited by 237
“statistical methods [23] and soft-computing-based intelligent algorithms [24], were implemented for ELF.”
MethodMobile Energy Storage Scheduling and Operation in Active Distribution Systems
Abdeltawab, H. H., & Mohamed, Y. A.-R. I. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2682779 · Cited by 219
“9(b), are taken from the typical historical data provided in [26].”
BackgroundPinheiro, M. G., Madeira, S. C., & Francisco, A. P. (2023) · Applied Energy · doi:10.1016/j.apenergy.2022.120493 · Cited by 119
Metadata
- Authors
- Chakhchoukh, Y., Panciatici, P., & Mili, L.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2011-08
- Volume
- 26
- Issue
- 3
- Pages
- 982-991
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2096501632
- Cited by
- 202
- References
- 1
- FWCI
- 2.74
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.