Active-reactive optimal power flow in distribution networks with embedded generation and battery storage
Abstract
Due to environmental and fuel cost concerns more and more wind- and solar-based generation units are embedded in distribution networks (DNs). However, a part of such an embedded generation would be curtailed due to system constraints and variations of the energy penetration. This part of energy can be recovered by introducing energy storage systems (ESSs) and an optimal dispatch of both active and reactive powers. Therefore, we propose a combined problem formulation for active-reactive optimal power flow (A-R-OPF) in DNs with embedded wind generation and battery storage. The solution provides an optimal operation strategy which ensures the feasibility and enhances the profit significantly. Results of a 41-bus distribution network are presented. It can be demonstrated that more than 12% of energy losses and a large amount of reactive energy to be imported from the transmission network (TN) can be reduced using the proposed approach in comparison to the operation strategy where only active OPF is considered.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A BESS is a combination of a voltage source converter and a battery pack, such that active and reactive power can be controlled independently.
“The BESS is a combination of a voltage source converter and a battery pack, such that the active and reactive power can be controlled independently [4][5][6][7][8][9].”
From Dynamic Optimal Power Dispatch in Unbalanced Distribution Networks with Single-Phase Solar PV Units and BESS (2023) · cites this paper as [5]
Cited by
Sorted by citations
Radosavljević, J., Ktena, A., Gajić, M., Milovanović, M., & Živić, J. (2023) · Energies · doi:10.3390/en16114356 · Cited by 10 · see citing works
- Authors
- Gabash, A., & Li, P.
- Affiliations
- Technische Universität Ilmenau (DE)
- ORCID
- Venue
- IEEE Transactions on Power Systems
- Published
- 2012-11
- Volume
- 27
- Issue
- 4
- Pages
- 2026-2035
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W1996730948
- Cited by
- 335
- References
- 0
- Citations by year
- 2026: 4 · 2025: 9 · 2024: 12 · 2023: 20 · 2022: 14 · 2021: 33 · 2020: 30 · 2019: 31 · 2018: 39 · 2017: 42 · 2016: 43 · 2015: 23 · 2014: 20 · 2013: 12 · 2012: 3
- FWCI
- 11.86
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Systems (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power System Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Keywords
- distribution networks, distributed generation, wind energy, battery energy storage, energy storage systems, reactive power optimization, energy curtailment, energy loss, renewable energy integration
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review