The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Generator dynamic model validation and parameter calibration using phasor measurements at the point of connection
Abstract
Power system model quality is key to safe and reliable electricity delivery. A novel method using disturbance data recorded by phasor measurement units (PMUs) is proposed to improve the integrity of dynamic models, which consists of both model validation and model parameter identification. In the model validation step, event playback is applied to simulate the model's response for a rigorous comparison with measured response captured by PMUs. A large mismatch indicates model deficiency. In the parameter identification step, an automatic calibration method using the extended Kalman filter (EKF) techniques and trajectory sensitivity analysis is formulated to save significant effort and time from manual tuning. Case studies are presented to demonstrate that the proposed method has adequate performance for model validation and parameter calibration in terms of accuracy, good convergence speed and robustness with respect to measurement noises. The proposed method is cost-effective and complements traditional equipment testing for improving dynamic model quality.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A New Approach to Linear Filtering and Prediction Problems
Kalman, R. E. (1960) · Journal of Basic Engineering · doi:10.1115/1.3662552 · Cited by 31,751
Cited by
Power System Dynamic State Estimation: Motivations, Definitions, Methodologies, and Future Work
Zhao, J., Qi, J., Huang, Z., Meliopoulos, A. P. S., Gomez-Exposito, A., Netto, M., Mili, L., Abur, A., Terzija, V., Kamwa, I., et al. (2019) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2019.2894769 · Cited by 716
Self-citationSynchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art
Aminifar, F., Fotuhi-Firuzabad, M., Safdarian, A., Davoudi, A., & Shahidehpour, M. (2014) · IEEE Access · doi:10.1109/access.2015.2389659 · Cited by 261
Metadata
- Authors
- Huang, Z., Du, P., Kosterev, D., & Yang, S.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2013-05
- Volume
- 28
- Issue
- 2
- Pages
- 1939-1949
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2117485864
- Cited by
- 214
- References
- 1
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Generator dynamic model validation and parameter calibration using phasor measurements at the point of connection. https://app.cochat.ai/papers/10.1109/tpwrs.2013.2251482
- The paper
- Huang, Z., Du, P., Kosterev, D., & Yang, S. (2013). Generator dynamic model validation and parameter calibration using phasor measurements at the point of connection. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2013.2251482
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.