System of Systems Based Security-Constrained Unit Commitment Incorporating Active Distribution Grids
The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Abstract
In restructured power systems, the transmission and distribution grids are autonomously utilized by independent system operator (ISO) and distribution companies (DISCOs), respectively. As the operating condition of one grid influences the decisions made by operators of other grids, the ISO and DISCOs should collaborate and cooperate with each other in order to operate the entire power system in a secure and economic manner. According to the concept of system of systems (SoS) engineering, this paper presents a decentralized decision-making framework to determine a secure and economical hourly generation schedule for a transmission system encompassing numbers of active distribution grids. Taking into consideration the physical connections and shared information between ISO and DISCOs, an SoS-based SCUC framework is designed and a hierarchical optimization algorithm is presented to find optimal operating points of all independent systems in the SoS-based power system architecture. The numerical results show the effectiveness of the proposed SoS framework and solution methodology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Grigg, C., Wong, P., Albrecht, P., Allan, R., Bhavaraju, M., Billinton, R., Chen, Q., Fong, C., Haddad, S., Kuruganty, S., et al. (1999) · IEEE Transactions on Power Systems · doi:10.1109/59.780914 · Cited by 3,054
A Computationally Efficient Mixed-Integer Linear Formulation for the Thermal Unit Commitment Problem
Carrion, M., & Arroyo, J. M. (2006) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2006.876672 · Cited by 1,731 · cited 1×
“In this paper, the MIP model presented in [7] is applied to solve the regular SCUC of each independent system.”
MethodMarket Operations in Electric Power Systems: Forecasting, Scheduling, and Risk Management
Shahidehpour, M., Yamin, H., & Li, Z. (2002) · Wiley eBooks · doi:10.1002/047122412x · Cited by 1,616
Microgrids and Active Distribution Networks
Chowdhury, S., Chowdhury, S., & Crossley, P. A. (2009) · Institution of Engineering and Technology eBooks · doi:10.1049/pbrn006e · Cited by 1,198
Integration of Distributed Generation in the Power System
Bollen, M., & Hassan, F. (2011) · Wiley eBooks · doi:10.1002/9781118029039 · Cited by 740 · cited 1×
“These ADGs are making power systems more reliable and cost-effective, and are improving the power quality required by local loads [1]–[3].”
BackgroundOptimal response of a thermal unit to an electricity spot market
Arroyo, J. M., & Conejo, A. J. (2000) · IEEE Transactions on Power Systems · doi:10.1109/59.871739 · Cited by 536
Multiagent System for Real-Time Operation of a Microgrid in Real-Time Digital Simulator
Logenthiran, T., Srinivasan, D., Khambadkone, A. M., & Aung, H. N. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2189028 · Cited by 339 · cited 1×
“A two-stage scheduling algorithm for distribution grids was addressed in [13].”
BackgroundTosserams, S., Etman, L. F. P., Papalambros, P. Y., & Rooda, J. E. (2006) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-005-0579-0 · Cited by 312
Systems of Systems Engineering: Principles and Applications
Jamshidi, M. (2008) · Cited by 310
Convergence Properties of Analytical Target Cascading
Michelena, N., Park, H., & Papalambros, P. Y. (2003) · AIAA Journal · doi:10.2514/2.2025 · Cited by 304 · cited 1×
“The process of updating penalty multipliers in the outer loop and going back to the inner loop will control the entire optimization algorithm to converge to the optimal results [21].”
Cited by
A Survey of Distributed Optimization and Control Algorithms for Electric Power Systems
Molzahn, D. K., Dorfler, F., Sandberg, H., Low, S. H., Chakrabarti, S., Baldick, R., & Lavaei, J. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2017.2720471 · Cited by 1,273
Local flexibility markets: Literature review on concepts, models and clearing methods
Jin, X., Wu, Q., & Jia, H. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114387 · Cited by 373
Kargarian, A., Mohammadi, J., Guo, J., Chakrabarti, S., Barati, M., Hug, G., Kar, S., & Baldick, R. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2614904 · Cited by 302
Self-citationEnergy Management of Multiple Microgrids Based on a System of Systems Architecture
Zhao, B., Wang, X., Lin, D., Calvin, M. M., Morgan, J. C., Qin, R., & Wang, C. (2018) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2018.2840055 · Cited by 255
Bi-Level Two-Stage Robust Optimal Scheduling for AC/DC Hybrid Multi-Microgrids
Qiu, H., Zhao, B., Gu, W., & Bo, R. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2806973 · Cited by 169
“The penalty coefficient was updated in the iterative process of bi-level optimization in [27] and [32], where the initial penalty coefficient is 1, and it will be increased until convergence.”
BackgroundMethodNawaz, A., Wang, H., Wu, Q., & Kumar Ochani, M. (2020) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12233 · Cited by 42
Metadata
- Authors
- Kargarian, A., & Fu, Y.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2014-09
- Volume
- 29
- Issue
- 5
- Pages
- 2489-2498
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2332913600
- Cited by
- 216
- References
- 17
- FWCI
- 4.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.