Cascading Failure Analysis With DC Power Flow Model and Transient Stability Analysis
Open accessAbstract
When the modern electrical infrastructure is undergoing a migration to the Smart Grid, vulnerability and security concerns have also been raised regarding the cascading failure threats in this interconnected transmission system with complex communication and control challenge. The DC power flow-based model has been a popular model to study the cascading failure problem due to its efficiency, simplicity and scalability in simulations of such failures. However, due to the complex nature of the power system and cascading failures, the underlying assumptions in DC power flow-based cascading failure simulators (CFS) may fail to hold during the development of cascading failures. This paper compares the validity of a typical DC power flow-based CFS in cascading failure analysis with a new numerical metric defined as the critical moment (CM). The adopted CFS is first implemented to simulate system behavior after initial contingencies and to evaluate the utility of DC-CFS in cascading failure analysis. Then the DC-CFS is compared against another classic, more precise power system stability methodology, i.e., the transient stability analysis (TSA). The CM is introduced with a case study to assess the utilization of these two models for cascading failure analysis. Comparative simulations on the IEEE 39-bus and 68-bus benchmark reveal important consistency and discrepancy between these two approaches. Some suggestions are provided for using these two models in the power grid cascading failure analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Survey on Power System Blackout and Cascading Events: Research Motivations and Challenges
Haes Alhelou, H., Hamedani-Golshan, M. E., Njenda, T. C., & Siano, P. (2019) · Energies · doi:10.3390/en12040682 · Cited by 643
Cyber‐physical attacks and defences in the smart grid: a survey
He, H., & Yan, J. (2016) · IET Cyber-Physical Systems: Theory & Applications · doi:10.1049/iet-cps.2016.0019 · Cited by 454
Self-citationA Critical Review of Robustness in Power Grids Using Complex Networks Concepts
Cuadra, L., Salcedo-Sanz, S., Del Ser, J., Jiménez-Fernández, S., & Geem, Z. (2015) · Energies · doi:10.3390/en8099211 · Cited by 277
Dynamic Modeling of Cascading Failure in Power Systems
Song, J., Cotilla-Sanchez, E., Ghanavati, G., & Hines, P. D. H. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2439237 · Cited by 274
Q-Learning-Based Vulnerability Analysis of Smart Grid Against Sequential Topology Attacks
Yan, J., He, H., Zhong, X., & Tang, Y. (2017) · IEEE Transactions on Information Forensics and Security · doi:10.1109/tifs.2016.2607701 · Cited by 264
Self-citation
Metadata
- Authors
- Yan, J., Tang, Y., He, H., & Sun, Y.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2015-01
- Volume
- 30
- Issue
- 1
- Pages
- 285-297
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2313171746
- Cited by
- 224
- References
- 0
- FWCI
- 8.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cascading Failure Analysis With DC Power Flow Model and Transient Stability Analysis. https://app.cochat.ai/papers/10.1109/tpwrs.2014.2322082
- The paper
- Yan, J., Tang, Y., He, H., & Sun, Y. (2015). Cascading Failure Analysis With DC Power Flow Model and Transient Stability Analysis. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2014.2322082
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.