Aggregate Flexibility of Thermostatically Controlled Loads
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
It is widely accepted that thermostatically controlled loads (TCLs) can be used to provide regulation reserve to the grid. We first argue that the aggregate flexibility offered by a collection of TCLs can be succinctly modeled as a stochastic battery with dissipation. We next characterize the power limits and energy capacity of this battery model in terms of TCL parameters and random exogenous variables such as ambient temperature and user-specified set-points. We then describe a direct load control architecture for regulation service provision. Here, we use a priority-stack-based control framework to select which TCLs to control at any time. The control objective is for the aggregate power deviation from baseline to track an automatic generation control signal supplied by the system operator. Simulation studies suggest the practical promise of our methods.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“There is an abundant literature suggesting models and identifying the potential of the residential sector to participate in DR programs in order to provide various system services such as regulation and spinning reserves.”
From An overview of Demand Response: Key-elements and international experience (2017) · cites this paper as [71]
Citations
Cites
Callaway, D. S. (2009) · Energy Conversion and Management · doi:10.1016/j.enconman.2008.12.012 · Cited by 759 · cited 4×
“See [10], [11], and [15] for more details on the model.”
BackgroundMethodInfluentialAn Evaluation of the HVAC Load Potential for Providing Load Balancing Service
Lu, N. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2183649 · Cited by 739 · cited 1×
“Temperature-based and/or time-based priority control methods that are closely related or identical to this paper were developed in [15], [18], and [19].”
MethodOperational Impacts of Wind Generation on California Power Systems
Makarov, Y. V., Loutan, C., Ma, J., & de Mello, P. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2016364 · Cited by 614
State Estimation and Control of Electric Loads to Manage Real-Time Energy Imbalance
Mathieu, J. L., Koch, S., & Callaway, D. S. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2204074 · Cited by 574
Aggregated Modeling and Control of Air Conditioning Loads for Demand Response
Zhang, W., Lian, J., Chang, C.-Y., & Kalsi, K. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2266121 · Cited by 472 · cited 2×
“There is a substantial body of work on models for TCLs and TCL aggregations [11]–[16].”
BackgroundMethodUtility Wind Integration and Operating Impact State of the Art
Smith, J. C., Milligan, M. R., DeMeo, E. A., & Parsons, B. (2007) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2007.901598 · Cited by 466 · cited 1×
“It is widely accepted that the deep penetration of renewable generation will substantially increase the need for ancillary services [2]–[4].”
BackgroundVolatility of power grids under real-time pricing
Roozbehani, M., Dahleh, M. A., & Mitter, S. K. (2012) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2195037 · Cited by 335
Malhame, R., & Chong, C.-Y. (1985) · IEEE Transactions on Automatic Control · doi:10.1109/tac.1985.1104071 · Cited by 307 · cited 3×
“See [10], [11], and [15] for more details on the model.”
BackgroundModeling and Control of Aggregate Air Conditioning Loads for Robust Renewable Power Management
Bashash, S., & Fathy, H. K. (2013) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2012.2204261 · Cited by 291
Development of physical-based demand response-enabled residential load models
Shao, S., Pipattanasomporn, M., & Rahman, S. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2012.2208232 · Cited by 276
Research works printed but not linked: 9
- 0, PJM Regulation Data
- 0, Smart AC Program
- helman, 2010, Resource and transmission planning to achieve a 33% RPS in California-ISO modeling tools and planning framework, Proc FERC Tech Conf Planning Models Softw
- 2010, U S Energy Information Administration Annual Energy Review
- 0, Buildings Energy Data Book
- kirby, 2007, Ancillary Services Technical and Commercial Insights
- 2007, Data Collection for Demand Side Management for Quantifying its Influence on Reliability Results and Recommendations Tech Rep
- mathieu, 2012, Using residential electric loads for fast demand response: The potential resource and revenues, the costs, policy recommendations, 2012 ACEEE Summer Study on Energy Efficiency in Buildings
- macdonald, 2012, Demand response providing ancillary services, Grid-interop 2012
Cited by
Smart Grids: A Cyber–Physical Systems Perspective
Yu, X., & Xue, Y. (2016) · Proceedings of the IEEE · doi:10.1109/jproc.2015.2503119 · Cited by 717
“Another effective approach is the distributed model predictive control which considers future trends into control actions [44], [45].”
BackgroundAn overview of Demand Response: Key-elements and international experience
Paterakis, N. G., Erdinç, O., & Catalão, J. P. S. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.167 · Cited by 640
“For example, [69] investigates the potential of a household equipped with a HEMS to provide frequency response, [70] examines the potential of load flexibility provided by smart appliances in order to participate in reserve services, [71] employs a model of ACs in order to provide reserves by DLC through an aggregator…”
MethodHeat pumps and our low-carbon future: A comprehensive review
Gaur, A. S., Fitiwi, D. Z., & Curtis, J. (2021) · Energy Research & Social Science · doi:10.1016/j.erss.2020.101764 · Cited by 533
On heat pumps in smart grids: A review
Fischer, D., & Madani, H. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.11.182 · Cited by 445
A Geometric Approach to Aggregate Flexibility Modeling of Thermostatically Controlled Loads
Zhao, L., Zhang, W., Hao, H., & Kalsi, K. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2017.2674699 · Cited by 355
“Our approach (Theorems 2–4) includes the approach proposed in [1], [2] as a special case.”
BackgroundMethodInfluentialSelf-citation
Metadata
- Authors
- Hao, H., Sanandaji, B. M., Poolla, K., & Vincent, T. L.
- Affiliations
- University of California, Berkeley (US)
- Colorado School of Mines (US)
- Venue
- IEEE Transactions on Power Systems
- Published
- 2015-01
- Volume
- 30
- Issue
- 1
- Pages
- 189-198
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2327685928
- Cited by
- 733
- References
- 19
- Citations by year
- 2026: 45 · 2025: 38 · 2024: 52 · 2023: 49 · 2022: 58 · 2021: 78 · 2020: 96 · 2019: 87 · 2018: 66 · 2017: 69 · 2016: 48 · 2015: 38
- FWCI
- 28.69
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Systems (publishedVersion)
- Funders
- EPRI
- CERTS
- PSERC
- NSF (CNS-0931748, EECS-1129061, CPS-1239178, CNS-1239274)
- Republic of Singapore National Research Foundation
- Robert Bosch LLC
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Keywords
- thermostatically controlled loads, demand response, regulation reserves, energy dissipation, power limits, energy capacity, direct load control, automatic generation control, ambient temperature, set-point control
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.