The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Placement of Remote-Controlled Switches to Enhance Distribution System Restoration Capability
Abstract
A smart distribution system should restore service to interrupted customers as quickly as possible after an outage. Upgrading manual switches to remote-controlled switches (RCSs) enhances restoration capability. The placement of RCSs should consider both functional and economic requirements. This paper presents a systematic method to determine the set of switches to be upgraded for an existing distribution system. The maximum restoration capability is achieved by upgrading a near-minimum number of manual switches to RCSs. The RCS placement problem is formulated as a weighed set cover (WSC) problem. A greedy algorithm with a polynomial-time computational efficiency is designed to generate a near-optimal solution for the WSC problem. A 3-feeder 9-node test system and a 4-feeder 1069-node unbalanced test system with microgrids are used to validate the effectiveness of the proposed method.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Introduction to Genetic Algorithms
Mitchell, M. (1996) · doi:10.7551/mitpress/3927.001.0001 · Cited by 11,340
Cited by
Microgrids for Service Restoration to Critical Load in a Resilient Distribution System
Xu, Y., Liu, C.-C., Schneider, K. P., Tuffner, F. K., & Ton, D. T. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2591531 · Cited by 476
Self-citationResilience-Oriented Critical Load Restoration Using Microgrids in Distribution Systems
Gao, H., Chen, Y., Xu, Y., & Liu, C.-C. (2016) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2550625 · Cited by 442
Self-citationNetworked Microgrids for Grid Resilience, Robustness, and Efficiency: A Review
Chen, B., Wang, J., Lu, X., Chen, C., & Zhao, S. (2021) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2020.3010570 · Cited by 344
Chen, C., Wang, J., & Ton, D. (2017) · Proceedings of the IEEE · doi:10.1109/jproc.2017.2684780 · Cited by 293
Self-citationCoordinating Multiple Sources for Service Restoration to Enhance Resilience of Distribution Systems
Wang, Y., Xu, Y., He, J., Liu, C.-C., Schneider, K. P., Hong, M., & Ton, D. T. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2019.2891515 · Cited by 291
Self-citation
Metadata
- Authors
- Xu, Y., Liu, C.-C., Schneider, K. P., & Ton, D. T.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2016-03
- Volume
- 31
- Issue
- 2
- Pages
- 1139-1150
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2009742025
- Cited by
- 173
- References
- 1
- FWCI
- 7.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Placement of Remote-Controlled Switches to Enhance Distribution System Restoration Capability. https://app.cochat.ai/papers/10.1109/tpwrs.2015.2419616
- The paper
- Xu, Y., Liu, C.-C., Schneider, K. P., & Ton, D. T. (2016). Placement of Remote-Controlled Switches to Enhance Distribution System Restoration Capability. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2015.2419616
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.