The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Switching Markov Gaussian Models for Dynamic Power System Inertia Estimation
Open accessAbstract
Future power systems could benefit considerably from having a continuous real-time estimate of system inertia. If realized, this could provide reference inputs to proactive control and protection systems which could enhance not only system stability but also operational economics through, for example, more informed ancillary reserve planning using knowledge of prevailing system conditions and stability margins. Performing these predictions in real time is a significant challenge owing to the complex stochastic and temporal relationships between available measurements. This paper proposes a statistical model capable of estimating system inertia in real time through observed steady-state and relatively small frequency variations; it is trained to learn the features that inter-relate steady-state averaged frequency variations and system inertia, using historical system data demonstrated over two consecutive years. The proposed algorithm is formulated as a Gaussian Mixture Model with temporal dependence encoded as Markov chains. Applied to the U.K. power system, it produces an optimized mean squared error within 0.1 s2for 95% of the daily estimation if being calibrated on a half-hourly basis and maintains robustness through measurement interruptions of up to a period of two hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kass, R. E., & Raftery, A. E. (1995) · Journal of the American Statistical Association · doi:10.1080/01621459.1995.10476572 · Cited by 12,558
McLachlan, G., & Peel, D. (2000) · Wiley Series in Probability and Statistics · doi:10.1002/0471721182 · Cited by 10,991
Cited by
Review on deep learning applications in frequency analysis and control of modern power system
Zhang, Y., Shi, X., Zhang, H., Cao, Y., & Terzija, V. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107744 · Cited by 295
Tan, B., Zhao, J., Netto, M., Krishnan, V., Terzija, V., & Zhang, Y. (2022) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2021.107362 · Cited by 261
Metadata
- Authors
- Cao, X., Stephen, B., Abdulhadi, I. F., Booth, C. D., & Burt, G. M.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2016-09
- Volume
- 31
- Issue
- 5
- Pages
- 3394-3403
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2199118834
- Cited by
- 164
- References
- 2
- FWCI
- 1.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Switching Markov Gaussian Models for Dynamic Power System Inertia Estimation. https://app.cochat.ai/papers/10.1109/tpwrs.2015.2501458
- The paper
- Cao, X., Stephen, B., Abdulhadi, I. F., Booth, C. D., & Burt, G. M. (2016). Switching Markov Gaussian Models for Dynamic Power System Inertia Estimation. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2015.2501458
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.