Primary Frequency Response in Capacity Expansion with Energy Storage
Abstract
Massive integration of renewable energy resources calls for new operating and planning paradigms, which address reduced controllability and increased uncertainty on the generation side. On the other hand, emerging energy storage technologies can provide additional flexibility. Therefore, generation and storage expansion models need to be coordinated to ensure sufficiency of system-wide response capabilities within different regulation intervals. This paper proposes a coordinated generation and storage expansion formulation considering primary frequency response constraints. This is a stochastic mixed-integer linear program solved using an off-the-shelf solver. The proposed formulation is compared to the case when primary frequency response is neglected. The case study performed for an eight-zone ISO New England test system quantifies the value of energy storage simultaneously providing primary frequency response and spatio-temporal arbitrage.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The linearization of the product of a continuous and a binary variable has been previously done.
“The linearization of the product of a continuous and a binary variable has been previously done, for instance, in [40].”
From Integration of Electric Vehicles in Low-Voltage Distribution Networks Considering Voltage Management (2020) · cites this paper as [40]
Cited by
Sorted by citations
Integration of Electric Vehicles in Low-Voltage Distribution Networks Considering Voltage Management
Carrión, M., Zárate-Miñano, R., & Domínguez, R. (2020) · Energies · doi:10.3390/en13164125 · Cited by 18 · see citing works
“The linearization of the product of a continuous and a binary variable has been previously done, for instance, in [40].”
BackgroundSelf-citation
- Authors
- Carrion, M., Dvorkin, Y., & Pandzic, H.
- Affiliations
- New York University (US)
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-03
- Volume
- 33
- Issue
- 2
- Pages
- 1824-1835
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2744197839
- Cited by
- 70
- References
- 0
- Citations by year
- 2026: 2 · 2025: 9 · 2024: 9 · 2023: 8 · 2022: 5 · 2021: 10 · 2020: 14 · 2019: 6 · 2018: 7
- FWCI
- 3.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Power Systems (publishedVersion)
- Funders
- Hrvatska Zaklada za Znanost
- Croatian TSO
- Smart Integration of RENewables SIREN (I-2538-2015)
- Ministry of Economy and Competitiveness of Spain (DPI2015-71280-R)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Power System Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Integrated Energy Systems Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
- Keywords
- primary frequency response, energy storage, capacity expansion, renewable energy integration, stochastic mixed-integer linear programming, power system flexibility
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review