A Distributionally Robust Chance-Constrained MILP Model for Multistage Distribution System Planning With Uncertain Renewables and Loads
The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.
Abstract
Successful transition to active distribution networks (ADNs) requires a planning methodology that includes an accurate network model and accounts for the major sources of uncertainty. Considering these two essential features, this paper proposes a novel model for the multistage distribution expansion planning (MDEP) problem, which is able to jointly expand both the network assets (feeders and substations) and renewable/conventional distributed generators. With respect to network characteristics, the proposed planning model employs a convex conic quadratic format of ac power flow equations that is linearized using a highly accurate polyhedral-based linearization method. Furthermore, a chance-constrained programming approach is utilized to deal with the uncertain renewables and loads. In this regard, as the probability distribution functions of uncertain parameters are not perfectly known, a distributionally robust (DR) reformulation is proposed for the chance constraints that guarantees the robustness of the expansion plans against all uncertainty distributions defined within a moment-based ambiguity set. Effective linearization techniques are also devised to eliminate the nonlinearities of the proposed DR reformulation, which yields a distributionally robust chance-constrained mixed-integer linear programming model for the MDEP problem of ADNs. Finally, the 24-node and 138-node test systems are used to demonstrate the effectiveness of the proposed planning methodology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chance-Constrained Programming
Charnes, A., & Cooper, W. W. (1959) · Management Science · doi:10.1287/mnsc.6.1.73 · Cited by 2,742
Optimal capacitor placement on radial distribution systems
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19265 · Cited by 2,062 · cited 2×
“Note that DistFlow branch equations are an exact representation of the AC power flow equations in a radial distribution network [34]–[36].”
BackgroundBranch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541 · cited 2×
“The detailed proof of the exactness of this relaxation technique can be found in [38].”
BackgroundMethodAdjustable robust solutions of uncertain linear programs
Ben-Tal, A., Goryashko, A., Guslitzer, E., & Nemirovski, A. (2004) · Mathematical Programming · doi:10.1007/s10107-003-0454-y · Cited by 1,380 · cited 1×
“On the other hand, H̃(χ̃) can be defined as an affine function of χ̃ (see [40], [41]):”
Adjustable robust solutions of uncertain linear programs
Ben-TalA., GoryashkoA., GuslitzerE., et al. (2004) · Mathematical Programming · doi:10.5555/2990016.3114320 · Cited by 849
Chance-Constrained Optimal Power Flow: Risk-Aware Network Control under Uncertainty
Bienstock, D., Chertkov, M., & Harnett, S. (2014) · SIAM Review · doi:10.1137/130910312 · Cited by 496
Data-driven chance constrained stochastic program
Jiang, R., & Guan, Y. (2016) · Mathematical Programming · doi:10.1007/s10107-015-0929-7 · Cited by 485 · cited 4×
“propose a distributionally robust (DR) reformulation for CCs, which not only is exact, but also does not make any assumptions about the uncertainty distributions [31].”
BackgroundMethodInfluentialOn Duality Theory of Conic Linear Problems
Shapiro, A. (2001) · Nonconvex optimization and its applications · doi:10.1007/978-1-4757-3403-4_7 · Cited by 423 · cited 2×
“After that, using the duality theory of conic linear programming problems [32] and the S-Lemma [33], the DR variants of CCs are equivalently reformulated as a number of explicit nonlinear constraints.”
MethodSedghi, M., Ahmadian, A., & Aliakbar-Golkar, M. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2404533 · Cited by 422 · cited 4×
“, AC power flow equations and energy losses), but they are formulated as mixed-integer nonlinear programming (MINLP) problems that are very difficult to solve [1], [6]–[9].”
BackgroundMethodInfluentialGeorgilakis, P. S., & Hatziargyriou, N. D. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.12.010 · Cited by 414 · cited 10×
“A linear MDEP model will provide dependable expansion plans for ADNs only if it incorporates a complete study of the network operation based on AC power flow equations.”
BackgroundInfluential
Metadata
- Authors
- Zare, A., Chung, C. Y., Zhan, J., & Faried, S. O.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-09
- Volume
- 33
- Issue
- 5
- Pages
- 5248-5262
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2783167261
- Cited by
- 160
- References
- 31
- FWCI
- 6.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Distributionally Robust Chance-Constrained MILP Model for Multistage Distribution System Planning With Uncertain Renewables and Loads. https://app.cochat.ai/papers/10.1109/tpwrs.2018.2792938
- The paper
- Zare, A., Chung, C. Y., Zhan, J., & Faried, S. O. (2018). A Distributionally Robust Chance-Constrained MILP Model for Multistage Distribution System Planning With Uncertain Renewables and Loads. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2018.2792938
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.