Robust Network Hardening Strategy for Enhancing Resilience of Integrated Electricity and Natural Gas Distribution Systems Against Natural Disasters
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Recent revolution of the electricity distribution sector, especially a deeper penetration of gas-fired distributed generations (DGs), intensifies the interdependence of electricity on natural gas distribution systems. Such integrated electricity and natural gas distribution systems (IENDS) are facing with significant threats from frequent natural disasters that cause enormous economic losses. Network hardening is regarded as an effective technique for enhancing resilience of IENDSs against natural disasters. This paper presents a trilevel robust optimization-based network hardening model for minimizing worst-case total weighted electricity and gas load shedding of IENDSs with respect to hardening budget limits and random damages caused by disasters of different severity levels. Specifically, distinct failure probabilities of overhead power lines and underground gas pipelines are considered, while DGs and gas storages are modeled as effective emergency response resources for supplying high-priority electricity/gas loads during disasters. The proposed model is solved by a column-and-constraint generation approach, in which nonlinear gas network constraints are linearized via Taylor series expansion. Numerical case studies evaluate the proposed robust hardening strategy against natural disasters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Branch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541 · cited 1×
“The reason is that in order to ensure solution exactness of convex relaxation, the objective function needs to be formulated as minimizing total costs or losses [41], [42], while the objective of this paper is to minimize TWLS of the IENDS.”
BackgroundResearch on Resilience of Power Systems Under Natural Disasters—A Review
Wang, Y., Chen, C., Wang, J., & Baldick, R. (2016) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2429656 · Cited by 1,116 · cited 3×
“In literature [2], [10], [14], [15], researchers typically model impact of different types of natural disasters via the number of system components that are damaged.”
Background
Cited by
Review of studies on the resilience of urban critical infrastructure networks
Liu, W., & Song, Z. (2020) · Reliability Engineering & System Safety · doi:10.1016/j.ress.2019.106617 · Cited by 320
Metadata
- Authors
- He, C., Dai, C., Wu, L., & Liu, T.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2018-09
- Volume
- 33
- Issue
- 5
- Pages
- 5787-5798
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2795032369
- Cited by
- 179
- References
- 2
- FWCI
- 14.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.