Efficient Distribution System Optimal Power Flow With Discrete Control of Load Tap Changers
The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
Load tap changers (LTCs) are commonly used for voltage control in distribution systems. The mechanical relays on LTCs are controlled in discrete steps; hence, distribution optimal power flow (DOPF) formulations require LTCs to be modeled with integer variables. Integer variables are generally ignored or relaxed and rounded off to reduce the computational burden in DOPF models. However, in this paper, we highlight and overcome complex infeasibility issues caused by rounding methods. Moreover, recent advances in convex optimization have improved the computational tractability of the DOPF problem. In this paper, we develop and analyze numerical efficiency of different but exact formulations for incorporating LTCs as integer control assets in a relaxed second-order cone program (SOCP) version of the DOPF model. The resulting formulation becomes a mixed-integer SOCP (MISOCP), which is computationally tractable compared to mixed-integer non-linear program (MINLP). To recover the exact optimal solution in the proposed MISOCP-DOPF model, a McCormick relaxation is employed within a sequential bound-tightening algorithm. We show that solutions obtained from MISOCP-DOPF are always ac feasible. Thus, the MISOCP-DOPF yields optimal and realistic ac solutions, and is validated in large distribution feeders and is compared to MINLP counterpart.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optimal capacitor placement on radial distribution systems
Baran, M. E., & Wu, F. F. (1989) · IEEE Transactions on Power Delivery · doi:10.1109/61.19265 · Cited by 2,062 · cited 2×
“Linear approximations of DOPF problem have also been widely studied [21], [22].”
BackgroundMethodBranch Flow Model: Relaxations and Convexification—Part I
Farivar, M., & Low, S. H. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2255317 · Cited by 1,541 · cited 5×
“In radial distribution systems, the relaxations are proven to be exact under the conditions that there are no upper bound on the loads [27], [28].”
BackgroundMethodInfluential
Cited by
A comprehensive multi-period optimal power flow framework for smart LV networks
Avramidis, I. I., Capitanescu, F., & Deconinck, G. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3040502 · Cited by 19
Cha, J., Han, C., Song, S., Kang, S., Lee, D., Chang, M., & Jang, G. (2024) · Sustainable Energy, Grids and Networks · doi:10.1016/j.segan.2024.101361 · Cited by 14
Ciocia, A., Chicco, G., & Spertino, F. (2020) · 2020 International Conference on Smart Energy Systems and Technologies (SEST) · doi:10.1109/sest48500.2020.9203231 · Cited by 11
Metadata
- Authors
- Shukla, S. R., Paudyal, S., & Almassalkhi, M. R.
- Venue
- IEEE Transactions on Power Systems
- Published
- 2019-07
- Volume
- 34
- Issue
- 4
- Pages
- 2970-2979
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W2911467671
- Cited by
- 67
- References
- 2
- FWCI
- 3.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Efficient Distribution System Optimal Power Flow With Discrete Control of Load Tap Changers. https://app.cochat.ai/papers/10.1109/tpwrs.2019.2894674
- The paper
- Shukla, S. R., Paudyal, S., & Almassalkhi, M. R. (2019). Efficient Distribution System Optimal Power Flow With Discrete Control of Load Tap Changers. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2019.2894674
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.