The DOI matches its Crossref record.
Data-Driven-Aided Linear Three-Phase Power Flow Model for Distribution Power Systems
Abstract
Distribution power systems (DPSs) are generally unbalanced, and their loads may have notable static voltage characteristics (ZIP loads). Hence, although many papers have focused on linear single-phase power flow models, it is still necessary to study linear three-phase distribution power flow models. This paper proposes a data-driven-aided linear three-phase power flow model for DPSs. We first formulate how to amalgamate data-driven techniques into a linear power flow equation to establish our linear model. This amalgamation makes our linear model independent of the assumptions commonly used in the literature (e.g., nodal voltages are nearly 1.0 p.u.); therefore, our model is characterized by relatively high accuracy, even when the assumptions become invalid. We then demonstrate how to apply our model to DPSs with ZIP loads. We also show that with the Huber penalty function employed, the adverse impact of bad data on our model's accuracy is significantly reduced, rendering our model robust to poor data quality. Case studies demonstrate that our model is generally more accurate, with 2- to 100-fold smaller errors, than most existing linear models, and remains fairly accurate even under poor data conditions. Our model also contributes to a rapid solution to DPS analyses and optimization problems.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The precondition | ∆ v k | < 1 allows the proposed algorithm to be applied to a wider range of distribution system operations with deepening DER penetration. This is in contrast with the conventional assumption made for passive distribution networks, which assumes a narrow operating range of voltage magnitudes constrained to float in [0.95,1.05] [11].”
From Taylor-Expansion-Based Robust Power Flow in Unbalanced Distribution Systems: A Hybrid Data-Aided Method (2024) · cites this paper as [11]
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 42
- 10.1109/TPWRS.2017.2776253 · DOI
- 10.1109/TPWRS.2018.2871182 · DOI
- 10.1109/TPWRS.2015.2407363 · DOI · Paper page
- 2018, System Operation Emphasising DSOTSO Interaction and Co-Ordination
- 10.1109/TPWRS.2016.2638923 · DOI
- 10.1109/ACCESS.2019.2909325 · DOI
- 10.1109/TPWRS.2016.2533540 · DOI
- 10.1109/TPWRS.2015.2394296 · DOI
- 10.1109/TPWRS.2020.3012894 · DOI
- 10.1109/TPWRS.2018.2823277 · DOI
- 10.1109/ALLERTON.2015.7447032 · DOI
- 10.1109/ACCESS.2018.2839641 · DOI
- 10.1109/61.25627 · DOI
- 10.1109/TPWRS.2015.2493520 · DOI
- 10.1109/CCECE.1998.685631 · DOI
- 10.1109/TPWRS.2019.2954453 · DOI
- 10.1109/TSG.2020.3039984 · DOI
- 10.1049/iet-gtd.2015.0388 · DOI
- 10.1109/ISGT-Asia.2013.6698739 · DOI
- 10.1109/TPWRS.2017.2718551 · DOI
- 10.1109/TPWRS.2014.2368572 · DOI
- 10.1109/TPWRS.2019.2939098 · DOI
- 10.1109/TPWRD.2014.2369500 · DOI
- 10.1109/TSTE.2018.2859036 · DOI
- 10.1109/TSG.2018.2805169 · DOI
- 10.1109/TPWRS.2020.2975455 · DOI
- 10.1109/TSG.2016.2572060 · DOI
- 10.1109/TPWRS.2018.2820059 · DOI
- 10.1201/9781420041736 · DOI · Paper page
- 10.1109/TPWRS.2017.2728618 · DOI
- 10.1007/978-1-4615-8071-3 · DOI
- 10.1109/IHMSC49165.2020.00062 · DOI
- 10.1017/cbo9780511804441 · DOI · Paper page
- 10.1109/TPWRS.2005.846157 · DOI
- 10.1109/MPAE.2004.1338120 · DOI
- 10.1109/TIA.2013.2279195 · DOI
- 10.1109/TSP.2010.2040671 · DOI
- 10.1109/TPWRS.2019.2902136 · DOI
- Khachiyan, 2009, FourierMotzkin elimination method, 1074
- 10.1109/TPWRS.2017.2721971 · DOI
- 10.1109/TSG.2016.2582221 · DOI
- 10.1016/j.ijepes.2020.106139 · DOI
Cited by
Sorted by citations
Chung, S., Zhang, Y., Wang, Z., & Ding, F. (2024) · arXiv · doi:10.48550/arxiv.2407.19253 · Cited by 3
“This is in contrast with the conventional assumption made for passive distribution networks, which assumes a narrow operating range of voltage magnitudes constrained to float in [0.95,1.05] [11].”
BackgroundMethodResultInfluential
Metadata
- Authors
- Liu, Y., Li, Z., & Zhou, Y.
- Affiliations
- Shandong University (CN)
- Venue
- IEEE Transactions on Power Systems
- Published
- 2022-07
- Volume
- 37
- Issue
- 4
- Pages
- 2783-2795
- ISSN
- 0885-8950 (ISSN-L)
- 1558-0679
- OpenAlex
- W3214745293
- Cited by
- 57
- References
- 0
- Citations by year
- 2026: 9 · 2025: 12 · 2024: 19 · 2023: 12 · 2022: 5
- FWCI
- 2.65
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Power Systems (publishedVersion)
- Funders
- National Natural Science Foundation of China (52007105)
- CSEE (JLB-2020–170)
- Shandong University
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid and Power Systems
- Keywords
- three-phase power flow, distribution power systems, ZIP loads, unbalanced distribution systems, data-driven modeling
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Data-Driven-Aided Linear Three-Phase Power Flow Model for Distribution Power Systems. https://app.cochat.ai/papers/10.1109/tpwrs.2021.3130301
- The paper
- Liu, Y., Li, Z., & Zhou, Y. (2022). Data-Driven-Aided Linear Three-Phase Power Flow Model for Distribution Power Systems. IEEE Transactions on Power Systems. https://doi.org/10.1109/tpwrs.2021.3130301