Decentralized Graphical-Representation-Enabled Multi-Agent Deep Reinforcement Learning for Robust Control of Cyber-Physical Systems
Abstract
Frequent and sizable voltage fluctuation, a common issue faced by the modern distribution system (DS), could lead to potential equipment failures and power interruption. This brings huge negative impact on the power supply reliability of the DS. Existing voltage regulation methods typically rely on the precise physical parameters, complete measurements, and perfect communication, all of these premises are difficult to meet in practice. To this end, a decentralized control method that is robust to measurement acquisition errors is developed for DS in this article. Specifically, a graph learning-based surrogate network is first built to simulate the power flow computing procedure and capture the structural characteristics of the DS. The centralized surrogate model is, then, divided into several decentralized representation networks according to the network partition results to obtain the robust embedding of the regional information of each subnetwork. Subsequently, the representation networks are embedded in the front of the actor networks of the multi-agent soft actor-critic algorithm, the agents of which are learned in a centralized fashion according to the reward value estimated by the centralized surrogate model. The systematic integration of the three components allows us to achieve cooperation between different subregions and robustness against anomalous measurements without the reliance on precise circuit parameters. Comparative studies on IEEE test system illustrate the…
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
Hybrid VVC approaches can substantially reduce computation and communication requirements compared with fully centralized OPF, while achieving better voltage regulation than fixed droop control.
“Overall, hybrid methods can substantially reduce computation and communication requirements compared with fully centralized OPF, while achieving better voltage regulation than fixed droop control”
From Physics-Informed AI-Based EV smart inverter control for two-stage Volt/Var coordination in renewable-rich active distribution networks (2026) · cites this paper as [24]
The performance of hybrid VVC methods depends on the update rate of the supervisory layer, the fidelity of network models/sensitivities, and the ability to maintain feasibility under forecast errors and fast operational changes.
“nevertheless, their performance depends on the update rate of the supervisory layer, the fidelity of network models/sensitivities, and the ability to maintain feasibility under forecast errors and fast operational changes.”
From Physics-Informed AI-Based EV smart inverter control for two-stage Volt/Var coordination in renewable-rich active distribution networks (2026) · cites this paper as [24]
Cited by
Sorted by citations
Zhong, Y., Qiu, J., Yang, Y., Zhang, C., Tao, Y., Sun, X., & Lai, S. (2026) · Energy and AI · doi:10.1016/j.egyai.2026.100869
- Authors
- Cao, D., Hu, J., Liu, Y., & Hu, W.
- Affiliations
- University of Electronic Science and Technology of China (CN)
- Venue
- IEEE Transactions on Reliability
- Published
- 2024-12
- Volume
- 73
- Issue
- 4
- Pages
- 1710-1720
- ISSN
- 0018-9529 (ISSN-L)
- 1558-1721
- OpenAlex
- W4391620691
- Cited by
- 14
- References
- 0
- Citations by year
- 2026: 5 · 2025: 9
- FWCI
- 1.45
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Reliability (publishedVersion)
- Funders
- National Natural Science Foundation of China (72331002)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Optimal Power Flow Distribution
- Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Power System Optimization and Stability
- Keywords
- voltage regulation, distribution systems, decentralized control, multi-agent deep reinforcement learning, soft actor-critic, graph learning, surrogate models, power flow analysis, measurement error, robustness, power supply reliability, network partitioning
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review