The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Toward Brain-Actuated Humanoid Robots: Asynchronous Direct Control Using an EEG-Based BCI
Abstract
The brain-computer interface (BCI) technique is a novel control interface to translate human intentions into appropriate motion commands for robotic systems. The aim of this study is to apply an asynchronous direct-control system for humanoid robot navigation using an electroencephalograph (EEG), based active BCI. The experimental procedures consist of offline training, online feedback testing, and real-time control sessions. The amplitude features from EEGs are extracted using power spectral analysis, while informative feature components are selected based on the Fisher ratio. The two classifiers are hierarchically structured to identify human intentions and trained to build an asynchronous BCI system. For the performance test, five healthy subjects controlled a humanoid robot navigation to reach a target goal in an indoor maze by using their EEGs based on real-time images obtained from a camera on the head of the robot. The experimental results showed that the subjects successfully controlled the humanoid robot in the indoor maze and reached the goal by using the proposed asynchronous EEG-based active BCI system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Brain–computer interfaces for communication and control
Wolpaw, J. R., Birbaumer, N., McFarland, D. J., Pfurtscheller, G., & Vaughan, T. M. (2002) · Clinical Neurophysiology · doi:10.1016/s1388-2457(02)00057-3 · Cited by 7,927
A review of classification algorithms for EEG-based brain–computer interfaces
Lotte, F., Congedo, M., Lécuyer, A., Lamarche, F., & Arnaldi, B. (2007) · Journal of Neural Engineering · doi:10.1088/1741-2560/4/2/r01 · Cited by 2,665
Townsend, G., LaPallo, B. K., Boulay, C. B., Krusienski, D. J., Frye, G. E., Hauser, C. K., Schwartz, N. E., Vaughan, T. M., Wolpaw, J. R., & Sellers, E. W. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.01.030 · Cited by 570 · cited 7×
“In that paper, a Fujitsu HOAP-2 humanoid robot chose a target box between a green and a red box by detecting P300 signals and then conveyed the box to a predefined location using a machine learning technique.”
BackgroundInfluentialAn empirical study of machine learning techniques for affect recognition in human–robot interaction
Rani, P., Liu, C., Sarkar, N., & Vanman, E. (2006) · Pattern Analysis and Applications · doi:10.1007/s10044-006-0025-y · Cited by 313
Cited by
Brain-Machine Interfaces: From Basic Science to Neuroprostheses and Neurorehabilitation
Lebedev, M. A., & Nicolelis, M. A. L. (2017) · Physiological Reviews · doi:10.1152/physrev.00027.2016 · Cited by 653
A survey of sensor fusion methods in wearable robotics
Novak, D., & Riener, R. (2015) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2014.08.012 · Cited by 252
A Generic Transferable EEG Decoder for Online Detection of Error Potential in Target Selection
Bhattacharyya, S., Konar, A., Tibarewala, D. N., & Hayashibe, M. (2017) · Frontiers in Neuroscience · doi:10.3389/fnins.2017.00226 · Cited by 43
Metadata
- Authors
- Chae, Y., Jeong, J., & Jo, S.
- Venue
- IEEE Transactions on Robotics
- Published
- 2012-10
- Volume
- 28
- Issue
- 5
- Pages
- 1131-1144
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W2001019798
- Cited by
- 211
- References
- 4
- FWCI
- 7.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.