The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Design and Modeling of Generalized Fiber-Reinforced Pneumatic Soft Actuators
Abstract
Soft actuators comprised of fluidic structures with fiber-reinforced elastomeric enclosures are seen throughout nature, exhibiting strength, power density, resilience, and diverse motions and forces. However, these structures are rarely used by engineers, in part due to the absence of a generalized understanding of their kinematics and forces. A small subset of soft actuators generating only extension or compression, popularly known as McKibben actuators, has been thoroughly investigated. This paper introduces the entire design space of actuators built with two families of fibers, of which McKibben actuators occupy a subset. The helix angle of the actuator's translation and rotation deformation is determined from the kinematics of the fiber deformation for all fiber angles as the actuator is pressurized. The volumetric transduction of the actuators, relating the output motion to change in contained volume, is analytically determined. The results are discretized to provide a designer with an easy to use design selection chart. The kinematics, force, and moment of the actuators are experimentally validated for all fiber angles.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement and modeling of McKibben pneumatic artificial muscles
Chou, C.-P., & Hannaford, B. (1996) · IEEE Transactions on Robotics and Automation · doi:10.1109/70.481753 · Cited by 1,589
Cited by
Bistable and Multistable Actuators for Soft Robots: Structures, Materials, and Functionalities
Chi, Y., Li, Y., Zhao, Y., Hong, Y., Tang, Y., & Yin, J. (2022) · Advanced Materials · doi:10.1002/adma.202110384 · Cited by 584
Automatic design of fiber-reinforced soft actuators for trajectory matching
Connolly, F., Walsh, C. J., & Bertoldi, K. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1615140114 · Cited by 512
Robotic Artificial Muscles: Current Progress and Future Perspectives
Zhang, J., Sheng, J., O'Neill, C. T., Walsh, C. J., Wood, R. J., Ryu, J.-H., Desai, J. P., & Yip, M. C. (2019) · IEEE Transactions on Robotics · doi:10.1109/tro.2019.2894371 · Cited by 398
Modeling, Design, and Development of Soft Pneumatic Actuators with Finite Element Method
Moseley, P., Florez, J. M., Sonar, H. A., Agarwal, G., Curtin, W., & Paik, J. (2016) · Advanced Engineering Materials · doi:10.1002/adem.201500503 · Cited by 276
Metadata
- Authors
- Bishop-Moser, J., & Kota, S.
- Venue
- IEEE Transactions on Robotics
- Published
- 2015-06
- Volume
- 31
- Issue
- 3
- Pages
- 536-545
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W1696514235
- Cited by
- 159
- References
- 1
- FWCI
- 4.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Design and Modeling of Generalized Fiber-Reinforced Pneumatic Soft Actuators. https://app.cochat.ai/papers/10.1109/tro.2015.2409452
- The paper
- Bishop-Moser, J., & Kota, S. (2015). Design and Modeling of Generalized Fiber-Reinforced Pneumatic Soft Actuators. IEEE Transactions on Robotics. https://doi.org/10.1109/tro.2015.2409452
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.