Force Sensor Integrated Surgical Forceps for Minimally Invasive Robotic Surgery
Abstract
This paper presents a novel surgical instrument integrated with a four-degree-of-freedom (DOF) force sensor. By adopting the capacitive transduction principle, the sensor enables the direct sensing of normal and shear forces at surgical instrument tips. Thus, three-DOF pulling forces and a single-DOF grasping force can be measured for haptic feedback control of robotic minimally invasive surgery systems. The sensor consists of four capacitive transducers, and all the transducers including analog signal processing units are embedded in small surgical instrument tips. The four-DOF force sensing is enabled thanks to the four capacitive transducers by using the force transformation method. In this study, the instrument is designed and manufactured to be adaptable to the open-source surgical robot platform, called Raven-II. In addition, the sensing system is experimentally validated through its application to the Raven-II by using a reference force sensor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly sensitive flexible pressure sensors with microstructured rubber dielectric layers
Mannsfeld, S. C. B., Tee, B. C.-K., Stoltenberg, R. M., Chen, C. V. H.-H., Barman, S., Muir, B. V. O., Sokolov, A. N., Reese, C., & Bao, Z. (2010) · Nature Materials · doi:10.1038/nmat2834 · Cited by 3,291
The benefit of force feedback in surgery: Examination of blunt dissection
Wagner, C. R., Stylopoulos, N., Jackson, P. G., & Howe, R. D. (2007) · Presence: Teleoperators and Virtual Environments · doi:10.1162/pres.16.3.252 · Cited by 169
Cited by
A decade retrospective of medical robotics research from 2010 to 2020
Dupont, P. E., Nelson, B. J., Goldfarb, M., Hannaford, B., Menciassi, A., O’Malley, M. K., Simaan, N., Valdastri, P., & Yang, G.-Z. (2021) · Science Robotics · doi:10.1126/scirobotics.abi8017 · Cited by 516
Self-citationArtificial intelligence surgery: how do we get to autonomous actions in surgery?
Gumbs, A. A., Frigerio, I., Spolverato, G., Croner, R., Illanes, A., Chouillard, E., & Elyan, E. (2021) · Sensors · doi:10.3390/s21165526 · Cited by 161
Metadata
- Authors
- Kim, U., Lee, D.-H., Yoon, W. J., Hannaford, B., & Choi, H. R.
- Venue
- IEEE Transactions on Robotics
- Published
- 2015-10
- Volume
- 31
- Issue
- 5
- Pages
- 1214-1224
- ISSN
- 1552-3098 (ISSN-L)
- 1941-0468
- OpenAlex
- W1610082327
- Cited by
- 239
- References
- 2
- FWCI
- 16.35
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Force Sensor Integrated Surgical Forceps for Minimally Invasive Robotic Surgery. https://app.cochat.ai/papers/10.1109/tro.2015.2473515
- The paper
- Kim, U., Lee, D.-H., Yoon, W. J., Hannaford, B., & Choi, H. R. (2015). Force Sensor Integrated Surgical Forceps for Minimally Invasive Robotic Surgery. IEEE Transactions on Robotics. https://doi.org/10.1109/tro.2015.2473515
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.