A Reliability Perspective of the Smart Grid
The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Increasing complexity of power grids, growing demand, and requirement for greater reliability, security and efficiency as well as environmental and energy sustainability concerns continue to highlight the need for a quantum leap in harnessing communication and information technologies. This leap toward a ¿smarter¿ grid is widely referred to as ¿smart grid.¿ A framework for cohesive integration of these technologies facilitates convergence of acutely needed standards, and implementation of necessary analytical capabilities. This paper critically reviews the reliability impacts of major smart grid resources such as renewables, demand response, and storage. We observe that an ideal mix of these resources leads to a flatter net demand that eventually accentuates reliability challenges further. A gridwide IT architectural framework is presented to meet these challenges while facilitating modern cybersecurity measures. This architecture supports a multitude of geographically and temporally coordinated hierarchical monitoring and control actions over time scales from milliseconds and up.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“In the U.S. wind is expected to grow from 31 TW h in 2008 to 1160 TW h by 2030, which stands for a target of 20% of the total supply, while solar capacity is anticipated to reach 16 GW by 2020 [86].”
From An overview of Demand Response: Key-elements and international experience (2017) · cites this paper as [86]
Citations
Cites
WACS-Wide-Area Stability and Voltage Control System: R&D and Online Demonstration
Taylor, C. W., Erickson, D. C., Martin, K. E., Wilson, R. E., & Venkatasubramanian, V. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.846338 · Cited by 369
Scalable security and accounting services for content-based publish/subscribe systems
Khurana, H. (2005) · ACM Symposium on Applied Computing · doi:10.1145/1066677.1066862 · Cited by 54 · cited 1×
“, for quick isolation of security-breached components and/or classes of applications and services; • role-based management of identity/authentication, access, and command level filtering; • evolving security life cycle [25] in response to evolving threats and infrastructure components through sufficiently frequent sec…”
BackgroundFramework for a self-healing power grid
Moslehi, K., Kumar, A. B. R., Shurtleff, D., Laufenberg, M. J., Bose, A., & Hirsch, P. (2005) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2005.1489709 · Cited by 34 · cited 2×
“In parallel with the above implementation trends, major standards initiatives are also underway sponsored by NIST [23], IEEE (IEEE 2030) [24], etc.”
BackgroundSelf-citationThe multi-agent systems for computer network security assurance: frameworks and case studies
Gorodetski, V. I., & Kotenko, I. V. (2003) · IEEE International Conference on Artificial Intelligence Systems (ICAIS) · doi:10.1109/icais.2002.1048117 · Cited by 30 · cited 1×
“, for quick isolation of security-breached components and/or classes of applications and services; • role-based management of identity/authentication, access, and command level filtering; • evolving security life cycle [25] in response to evolving threats and infrastructure components through sufficiently frequent sec…”
BackgroundWACS-wide-area stability and voltage control system: R&D and on-line demonstration
Taylor, C. W. (2004) · IEEE Power Engineering Society General Meeting · doi:10.1109/pes.2004.1372736 · Cited by 25 · cited 1×
“Such coordination is already pursued in an ad hoc manner [31], [32].”
Background
Research works printed but not linked: 30
- 0, Smart Grid Interoperability Standards Project
- arons, 2007, piloting a centralized remedial action scheme (c-ras) with emerging telecomm/protection technologies, OSISOFT User Conf
- 2007, Wide Area Monitoring and Control for Transmission Capability Enhancement
- 0, IEEE P2030 Draft Guide for Smart Grid Interoperability of Energy Technology and Information Technology Operation With the Electric Power System (EPS) and End-Use Applications and Loads
- marti, 2006, evaluation of advanced wind power forecasting models, European Wind Energy Conf
- 2005, The effects of integrating wind power on transmission system planning reliability and operations report on phase 2 System performance evaluation
- 1990, waiting for the sunrise (solar energy forecast), The Economist, 95
- 2008, Solar energy industry forecast Perspectives on U S solar market trajectory
- 2003, Executive summary Assessment of parabolic trough and power tower solar technology cost and performance forecasts
- 2007, Harnessing the power of demandHow ISOs and RTOs are integrating demand response into wholesale electricity markets
- gawel, 2007, tesla's tests confirm roadster's 245-mile range, Electron Des
- 0, Reliability Standards Critical Infrastructure Protection (CIP)
- 0, Data bus technical specifications for NASPInet phasor gateway technical specifications for NASPInet
- 0, Smart grid cyber security strategy and requirements
- 0, American Recovery and Reinvestment Act of 2009
- dasgupta, 2007, Immuno-inspired autonomic system for cyber defense information security
- 0, Smart Grid Systems
- lacommare, 2006, Cost of power interruptions to electricity consumers in the United States
- 0, North American SynchroPhasor Initiative
- 0, Recovery ActSmart Grid Investment Grant Program
- 2008, 20% Wind Energy by 2030
- 1996, Summary Statistics for the United States
- 0, title xiiismart grid, sec. 1301, statement of policy on modernization of electricity grid, Energy Independence and Security Act of 2007 (EISA)
- 2008, Annual report on US wind power installation cost and performance trends 2007
- 2009, Smart grid policy
- moslehi, 2004, Electricity Transmission in Deregulated Markets Challenges Opportunities and Necessary R&D
- 0, Transmission fast simulation and modeling (T-FSM) architectural requirements
- 0, Transmission fast simulation and modeling (T-FSM)Functional requirements document
- 0, Transmission fast simulation and modeling (T-FSM)Business case analysis
- creel, 2007, Assuring software systems security Life cycle considerations for government acquisitions
Cited by
Items 501–600 of 952
Mohamed, A. A., Sabillón, C., Golriz, A., Lavorato, M., Rider, M. J., & Venkatesh, B. (2022) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2022.3200869 · Cited by 8
“The planning for smart grids and microgrids on a large scale considering the reliability is explored as in [4] and [5].”
BackgroundAn Improved Reactive Power Sharing in an Isolated Microgrid with a Local Load Detection
Smadi, I. A., & Shehadeh, L. I. (2023) · Chinese Journal of Electrical Engineering · doi:10.23919/cjee.2023.000021 · Cited by 8
Roy, C., & Das, D. K. (2023) · International Conference on Energy, Power and Environment (ICEPE) · doi:10.1109/icepe57949.2023.10201652 · Cited by 8
“It helps to reduce the bill of electrical power generation, helps to restore electricity quickly after disturbances and also improves transmission efficiency as discussed in [4].”
BackgroundAnalysis of Flexibility Potential of a Cold Warehouse with Different Refrigeration Compressors
Khorsandnejad, E., Malzahn, R., Oldenburg, A.-K., Mittreiter, A., & Doetsch, C. (2023) · Energies · doi:10.3390/en17010085 · Cited by 8
On the application of massive MU-MIMO in the uplink of machine type communication systems
de Figueiredo, F. A. P., Cardoso, F. A. C. M., Lopes, R., & Miranda, J. P. (2015) · International Workshop on Telecommunications (IWT) · doi:10.1109/iwt.2015.7224559 · Cited by 8
“Reliability in smart grid and critical infrastructure monitoring, for instance, is often achievable only via dedicated landlines [8, 9].”
BackgroundSmart grids and power supply reliability: The impact of demand response on future power mixes
Bouckaert, S., Mazauric, V. G., Assoumou, E., & Mäızi, N. (2013) · IEEE Grenoble Conference · doi:10.1109/ptc.2013.6652216 · Cited by 8
“What is more, Smart Grids may increase the complexity of the power supply and impede its reliability [1], despite the fact that one of the main objectives of Smart Grids is to maintain or even improve”
BackgroundStatic state estimation of FACTS containing synchronized phasor measurement units
Zamora-Cardenas, E. A., & Fuerte‐Esquivel, C. R. (2012) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2012.6344938 · Cited by 8
Distributed smart grid architecture for delay and price sensitive power management
Master, N., Mounzer, J., & Bambos, N. (2014) · International Conference on Communications · doi:10.1109/icc.2014.6883892 · Cited by 8
“While battery storage is not yet a major part of the smart grid, many expect this technology to become more pervasive as the price decreases and as efficiency increases [11].”
BackgroundRamachandran, B., & Geng, A. (2014) · Power systems · doi:10.1007/978-981-287-302-6_2 · Cited by 8
“To accomplish these objectives, this chapter proposes a novel real time smart coordination approach using a receding time horizon method to coordinate multiple charging and discharging of PEVs while reducing system stresses that can severely impact grid reliability, security and performance [24].”
MethodQoS Model of WSNs Communication in Smart Distribution Grid
Fang, R., Wang, J., Sun, W., & Li, Q. (2016) · International Journal of Distributed Sensor Networks · doi:10.1155/2016/6926793 · Cited by 8
“Among them, one critical technology is real-time monitoring and control of power system [3– 5].”
BackgroundIntelligent State Space Pruning with local search for power system reliability evaluation
Green, R., Wang, L., & Alam, M. (2012) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope.2012.6465775 · Cited by 8
“), and electric transportation (electric vehicles (EVs), hybrid EVs (HEVs), and plug-in HEVs (PHEVS)) [21].”
BackgroundA unified distributed control for grid-connected and islanded modes in multi-bus AC microgrid
Hou, X., Han, H., Zhong, C., Yuan, W., Sun, Y., & Su, M. (2017) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2017.8216400 · Cited by 8
“INTRODUCTION In order to cope the increased energy shortage, the deteriorated environment and the diverse power supply, the concept of microgrid has attracted wide attention and been rapidly developed [1]-[3].”
BackgroundNieto-Martin, J., Kipouros, T., Savill, M. A., Woodruff, J., & Butans, J. (2018) · Complexity · doi:10.1155/2018/1543179 · Cited by 8
“From a bottom-up modelling approach [31, 32], the top-down perspective is a simplistic characterisation of how electrical power networks combine locational events and individual asset performance with high-level objectives like improving the CML of a certain congested area [33, 34].”
BackgroundYanine, F. F., Sánchez‐Squella, A., Parejo, A., Barrueto, A., Rother, H., & Sahoo, S. K. (2019) · Procedia Computer Science · doi:10.1016/j.procs.2019.11.265 · Cited by 9
Gupta, P. C., Banerjee, A., & Singh, P. P. (2018) · IEEE India Conference · doi:10.1109/indicon45594.2018.8986983 · Cited by 8
“Renewable energy modernizes our power system to ensure green, environment friendly [2-4].”
BackgroundWei, J., & Kundur, D. (2015) · Power systems · doi:10.1007/978-3-662-45928-7_9 · Cited by 8
“For emerging smart grid topologies this interface commonly occurs at the sensors and actuators, such as intelligent electronic devices (IEDs), remote terminal units (RTUs), programmable logic controllers (PLCs), that are acquiring data from and using data to control electrical components [73, 82, 84, 85, 93, 94].”
BackgroundModeling and control of DAB converter for solar micro-grid application
Behera, R. K., & Ojo, O. (2015) · International Conference on Power Electronics Systems and Applications · doi:10.1109/pesa.2015.7398899 · Cited by 10
“The DC sub-grid is fed from Solar panels and integrated into the grid using dual active bridge (DAB) converters [1]-[7].”
MethodRobust and Efficient Power Flow Convergence with G-min Stepping Homotopy Method
Jereminov, M., Terzakis, A., Wagner, M., Pandey, A., & Pileggi, L. (2019) · IEEE International Conference on Environment and Electrical Engineering and IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) · doi:10.1109/eeeic.2019.8783295 · Cited by 8
“H(x, μ) = (1 − μ)F(x) + μG(x), μ ∈ [0,1] (6)”
BackgroundDetection of Anomalies in Household Appliances from Disaggregated Load Consumption
Castangia, M., Sappa, R., Girmay, A. A., Camarda, C., Macii, E., & Patti, E. (2021) · International Conference on Smart Energy Systems and Technologies (SEST) · doi:10.1109/sest50973.2021.9543232 · Cited by 8
“On the one hand, grid operators can benefit from detailed power consumption information to perform a better scheduling of their resources, which can be better allocated depending on the specific end-user needs [3].”
BackgroundBangalore, P. (2011) · Chalmers Publication Library (Chalmers University of Technology) · Cited by 11
A Review of Blockchain-based Smart Grid: Applications,Opportunities, and Future DirectionsPreprint
Ullah, H. S., & Aslam, S. (2020) · arXiv (Cornell University) · doi:10.48550/arxiv.2002.05650 · Cited by 10
Contribution des Smart Grids à la transition énergétique : évaluation dans des scénarios long terme
Bouckaert, S. (2013) · theses.fr (ABES) · doi:10.70675/5b77cf29ze72az4c80z953czef426cec7b59 · Cited by 8
Smart Grids and Software Testing Process Models
Hrabovská, K., Šimková, N., Rossi, B., & Pitner, T. (2019) · Smart City Symposium Prague (SCSP) · doi:10.1109/scsp.2019.8805718 · Cited by 7
“We derived the testing requirements from a series of related research, covering these aspects of the SG, mainly focusing on the infrastructure, communication, and ICT support ([8], [5], [9], [21], [22], [23], [24], [25], [26]).”
BackgroundMethodYanine, F., Sahoo, S. K., Sánchez‐Squella, A., Barrueto, A., & Rao, C. K. (2023) · Frontiers in Energy Efficiency · doi:10.3389/fenef.2023.1258384 · Cited by 7
Jamil, M. U., Zahid, M., Chen, Z., Hu, S., Muhammad, A., Farhan, M., & Butt, M. U. (2024) · International Conference Power and Energy Systems Engineering · doi:10.1109/cpese62584.2024.10841215 · Cited by 7
Spínola, J., Faria, P., & Vale, Z. (2015) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2015.7286385 · Cited by 7
“According to [6] there's, essentially, four main resources that will have to be managed.”
BackgroundPAS: An Efficient Privacy-Preserving Multidimensional Aggregation Scheme for Smart Grid
Zhu, H., Liu, F., Yan, R., & Li, H. (2015) · International Journal of Distributed Sensor Networks · doi:10.1155/2015/915795 · Cited by 7
“Recently the appearance of smart grid has attracted plenty of countries’ interest and has been regarded as the next generation of power grid [3–8].”
BackgroundIntelligent meter placement for power quality estimation in smart grid
Ali, S., Weston, K., Marinakis, D., & Wu, K. (2013) · IEEE International Conference on Smart Grid Communications (SmartGridComm) · doi:10.1109/smartgridcomm.2013.6688015 · Cited by 7
“Due to our high dependence on electricity, the issue of reliability in electric networks has become a core research interest in the smart grid area [1].”
BackgroundTelaretti, E., Ippolito, M. G., Dusonchet, L., Favuzza, S., Sanseverino, E. R., Massaro, F., Zizzo, G., & Pecoraro, G. (2015) · AEIT International Annual Conference · doi:10.1109/aeit.2015.7415227 · Cited by 7
“Differently from energy-saving, DR does not change the energy consumption profile, since a portion of the energy saved is generally consumed at a more suitable time, resulting in a flatter load profile [11].”
BackgroundAn effective ensemble electricity theft detection algorithm for smart grid
Tsai, C., Lu, C.-T., Li, C., & Zhang, S. (2024) · IET Networks · doi:10.1049/ntw2.12132 · Cited by 7
Kahrobaee, S. (2014) · Lincoln (University of Nebraska) · Cited by 7
Self-Balancing Distributed Energy in Power Grids: An Architecture Based on Autonomic Computing
Pérez, J., Díaz, J., Vidal, C., Rodriguez, D., & Fernandez, D. (2014) · Hawaii International Conference on System Sciences (HICSS) · doi:10.1109/hicss.2014.301 · Cited by 7
“distributed ones [25].”
Hierarchical Model Predictive Control for Plug-and-Play Resource Distribution
Bendtsen, J. D., Trangbæk, K., & Stoustrup, J. (2011) · Lecture notes in control and information sciences · doi:10.1007/978-1-4471-2265-4_15 · Cited by 7
“We illustrate the approach by a specific example, a so-called “smart grid” electric power system, where consumers can vary their power consumption within certain bounds by allowing devices to store more or less energy at convenient times [8].”
BackgroundAn ILP Based Algorithm for Optimal Customer Selection for Demand Response in SmartGrids
Kuppannagari, S. R., Kannan, R., & Prasanna, V. K. (2015) · International Conference on Computational Science and Computational Intelligence (CSCI) · doi:10.1109/csci.2015.140 · Cited by 8
“Keywords: Demand Response, SmartGrid, Integer Linear Programming CSCI-ISOT: Late Breaking Papers I. INTRODUCTION With the advent of advanced metering technologies such as smart meters, the traditional power grids have transformed into complex interconnection systems.”
BackgroundPrivacy-preserving power request and trading by prepayment in smart grid
Zhang, X., Zhou, L., Li, S., Xue, K., & Yue, H. (2017) · IEEE/CIC International Conference on Communications in China (ICCC) · doi:10.1109/iccchina.2017.8330340 · Cited by 7
“Smart grid is regarded as the next generation of power grid which utilizes information and communication technologies to achieve a more efficient, reliable, flexible and sustainable system [1, 2].”
BackgroundAn Analysis of the Energy Storage for Improving the Reliability of Distribution Networks
Escalera, A., Prodanović, M., & Castronuovo, E. D. (2018) · IEEE PES Innovative Smart Grid Technologies Europe · doi:10.1109/isgteurope.2018.8571768 · Cited by 7
“Under these circumstances, the integration of energy storage helps to improve the reliability [3], [4], but the extent of the improvement needs to be analysed taking into account factors like ratings of renewable generation, size of energy storage and storage state of charge when the fault occurs.”
BackgroundVigna, I., Balest, J., Pasut, W., & Pernetti, R. (2020) · Energies · doi:10.3390/en13174312 · Cited by 7
Pareto optimization Strategy for Clustering of PV Prosumers in a Renewable Energy Community
Grasso, F., Lozito, G. M., Fulginei, F. R., & Talluri, G. (2022) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melecon53508.2022.9843063 · Cited by 7
An autonomous distributed control method based on tie‐set graph theory in future grid
Nakayama, K., Shinomiya, N., & Watanabe, H. (2012) · International Journal of Circuit Theory and Applications · doi:10.1002/cta.1818 · Cited by 7
“Integration of renewable resources including those natural energies from consumer premises should advance global energy sustainability [11].”
BackgroundDistributed algorithm for economic power dispatch including transmission losses
Xing, H., Mou, Y., Fu, M., & Lin, Z. (2015) · European Control Conference (ECC) · doi:10.1109/ecc.2015.7330683 · Cited by 7
“Future smart grid, which will likely incorporate numerous distributed generation systems, is a typical large scale system [2].”
BackgroundReal-time adaptive load shedding based on probabilistic overload estimation
Cepeda, J., Ramirez, D., & Colome, D. G. (2014) · IEEE PES Transmission & Distribution Conference and Exposition - Latin America (PES T&D-LA) · doi:10.1109/tdc-la.2014.6955190 · Cited by 7
Optimal Discrete Net-Load Balancing in Smart Grids with High PV Penetration
Kuppannagari, S. R., Kannan, R., & Prasanna, V. K. (2018) · ACM Transactions on Sensor Networks · doi:10.1145/3218583 · Cited by 8
“Technological advances such as the use of bidirectional AMI meters, allowing real-time remote monitoring and control, have transformed them into smart grids [31].”
BackgroundSecurity and Privacy Issues in Internet of Things
Zhu, L., Gai, K., & Li, M. (2019) · Springer eBooks · doi:10.1007/978-3-030-21766-2_3 · Cited by 7
Asymmetrical Three-Level Inverter SiC-Based Topology for High Performance Shunt Active Power Filter
Iturra, R. G., & Thiemann, P. J. (2019) · Energies · doi:10.3390/en13010141 · Cited by 7
“Numerous and complex challenges are imposed on power systems at present times: a steady increasing energy demand in industrial and residential applications [2–4], the integration of renewable energies systems (RESs) and distributed generation (DG) [5–7] and the assurance of high power quality [8,9] and reliability [10…”
BackgroundOlsen, R. L., Balachandran, K., Hald, S. L., López, J. G., Pedersen, J. M., & Stevanovic, M. (2014) · Studies in computational intelligence · doi:10.1007/978-3-662-44160-2_3 · Cited by 7
Microgrid system with voltages in quadrature
dos Santos, E. C., & Alibeik, M. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6646861 · Cited by 7
“An electric power system requires several goals in its optimized operation, such as high efficiency, high reliability, good quality of service, and high level of security [8].”
BackgroundModelling and Simulation of Smart Grids using Dymola/Modelica
Enerbäck, J., & Nilsson, O. (2013) · Lund University Publications Student Papers (Lund University) · Cited by 7
Topics in Residential Electric Demand Response
Horowitz, S. (2012) · KiltHub Repository · doi:10.1184/r1/6723944 · Cited by 11
Detection of false data injection attacks in smart grid cyber-physical systems
Li, B. (2019) · doi:10.32657/10220/47640 · Cited by 9
Fijani, R. F., Azimian, B., Ghotbi, E., & Wang, X. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1902.05028 · Cited by 7
“, a quick growth of sophisticated smart metering facilities and advanced two-ways communication technologies has made managing the energy in smart grids more flexible and more stimulating [5-7].”
BackgroundA Brief Introduction to Classification for Smart Grid
Tsai, C., Pelov, A. P., Chiang, M., Yang, C., & Hong, T. (2013) · Conference proceedings/Conference proceedings - IEEE International Conference on Systems, Man, and Cybernetics · doi:10.1109/smc.2013.495 · Cited by 6
“From the perspective of building a new grid, several standards [5], [6], [7] and architectures [8], [7], [9] have been developed in recent years.”
BackgroundClass topper optimizer for cost-efficient smart grid operation under renewable energy uncertainties
Roy, C., & Das, D. K. (2025) · Energy Efficiency · doi:10.1007/s12053-025-10336-y · Cited by 6
Predictive Smart Grid Control with Exact Aggregated Power Constraints
Trangbæk, K., Pedersen, M., Bendtsen, J. D., & Stoustrup, J. (2012) · Power systems · doi:10.1007/978-3-642-21578-0_21 · Cited by 6
Optimal geometric control of Dc microgrids
Bunker, K. J., & Weaver, W. W. (2014) · IEEE ... Workshop on Control and Modeling for Power Electronics · doi:10.1109/compel.2014.6877217 · Cited by 6
“Reliability is an important consideration as microgrids continue to be implemented [3].”
BackgroundMohamed, A. A. R. (2018) · IEEE Mediterranean Electrotechnical Conference (MELECON) · doi:10.1109/melcon.2018.8379108 · Cited by 6
Analysis of the Effects of the Home Energy Management System from an Open Innovation Perspective
Park, E.-S., Kim, B. R., Park, S.-H., & Kim, D. (2018) · Journal of Open Innovation Technology Market and Complexity · doi:10.3390/joitmc4030031 · Cited by 6
“Moslehi and Kumar [17] studied the impact of the introduction of smart grid on the existing power grid.”
BackgroundIntrusion Detection with Unsupervised Techniques for Network Management Protocols over Smart Grids
Vega, R., Chamoso, P., González‐Briones, A., Casteleiro‐Roca, J., Jove, E., Meizoso-López, M. D. C., Rodríguez-Gómez, B. A., Quintián, H., Herrero, Á., Matsui, K., et al. (2020) · Applied Sciences · doi:10.3390/app10072276 · Cited by 6
“Thus, smart electricity networks become part of a macro-concept of territorial dominance, such as that of smart cities [13].”
BackgroundOptimal Dynamic Load-Altering Attacks Against Power Systems
Katewa, V., & Pasqualetti, F. (2021) · Proceedings of the ... American Control Conference/Proceedings of the American Control Conference · doi:10.23919/acc50511.2021.9483046 · Cited by 6
“Security concerns arise in all sectors of power systems, from generation to distribution, control, and consumption [1]–[3].”
BackgroundSecure Aperiodic Sampling Control for Micro-Grids Under Abnormal Deception Cyber Attacks
Cai, X. F., Shi, K., She, K., Zhong, S., Park, P., Kwon, O., & Han, S. C. (2022) · IEEE Transactions on Circuits and Systems I Regular Papers · doi:10.1109/tcsi.2022.3230957 · Cited by 6
“As discussed above [5], [9], [10], [12], and [13], they have all conducted research on MGs-related issues and got good results.”
BackgroundPa, S. S., Yakoob, M. B., Seetharaman, M., Victor, J. D., Arumugam, K., & Muthukumaran, S. (2023) · doi:10.3390/ecp2023-14672 · Cited by 6
A Cost-Energy Trade-Off Model in Smart Energy Grids
Gentile, U., Marrone, S., Mazzocca, N., & Nardone, R. (2014) · International Conference on P2P, Parallel, Grid, Cloud and Internet Computing (3PGCIC) · doi:10.1109/3pgcic.2014.83 · Cited by 6
“Smart Grids answer the need of reducing environmental impact and operating costs [1] and of increasing security and reliability levels of the energy delivery [2].”
BackgroundIntegrated platform for automated sustainable demand response in smart grids
Zois, V., Frincu, M. E., & Prasanna, V. K. (2014) · doi:10.1109/iwies.2014.6957048 · Cited by 9
“Over the last years the traditional power grids have evolved to complex cyber-physical systems [7], [17] consisting of bi-directional smart meters that report energy consumption in real time.”
BackgroundImpact of signal attributes on autocorrelation matrix dimension for smart grid solutions
Jain, S. K., & Singh, S. N. (2011) · IEEE PES Innovative Smart Grid Technologies - India (ISGT India) · doi:10.1109/iset-india.2011.6145353 · Cited by 6
“The power system reliability and security are becoming more challenging in the modern grid [16].”
BackgroundIncreasing Social Awareness of Consumer Behaviors On Smart Grids Energy Systems
(2016) · International Journal of Renewable Energy Research · doi:10.20508/ijrer.v6i4.5154.g6951 · Cited by 6
“Higher quality of service—free of voltage sags and spikes as well as other disturbances and interruptions—to power an increasingly digital economy [5].”
BackgroundMethodOptimal load dispatch for industrial manufacturing process based on demand response in a smart grid
Lu, X., Zhou, K., Zhang, C., & Yang, S. (2018) · Journal of Renewable and Sustainable Energy · doi:10.1063/1.5023772 · Cited by 6
Constant &Reliable Power Supply by the Smart Grid Technology in Modern Power System
Bagdadee, A. H., Li, Z., & Abdalla, M. A. A. (2019) · IOP Conference Series Materials Science and Engineering · doi:10.1088/1757-899x/561/1/012088 · Cited by 7
“The model must be as simple as expected in this situation but must speak with all the highlights that are the basis of the reliability of the framework [8].”
BackgroundDoustmohammadi, H., & Foroud, A. A. (2020) · International Transactions on Electrical Energy Systems · doi:10.1002/2050-7038.12584 · Cited by 6
Incorporating solar home systems for smart grid applications
Alipuria, B., Asare-Bediako, B., de Groot, R. J. W., Sarker, M. J., Slootweg, J. G., & Kling, W. L. (2012) · International Universities Power Engineering Conference (UPEC) · doi:10.1109/upec.2012.6398440 · Cited by 6
“Such an advan need to include additional software and har working [11].”
BackgroundCyber Security Challenges in Heterogeneous ICT Infrastructures of Smart Grids
Skopik, F., & Langer, L. (2013) · Journal of Communications · doi:10.12720/jcm.8.8.463-472 · Cited by 6
A prognostic model for managing consumer electricity demand and smart grid reliability
Hansen, C. K. (2012) · IEEE Conference on Prognostics and Health Management · doi:10.1109/icphm.2012.6299514 · Cited by 6
“The smart grid introduces better integration of alternative energy sources and the deployment of two-way communication systems [1-5].”
BackgroundModel of Smart System Based On Smart Grid, Smart Meter and Wireless Based Smart Appliances
Rehman, R. M. N.-U. (2012) · IOSR Journal of Electrical and Electronics Engineering · doi:10.9790/1676-0150610 · Cited by 6
Reliability assessment of distribution systems incorporating feeder restoration actions
D’Agostino, F., Silvestro, F., Schneider, K. P., Liu, C., Xu, Y., & Ton, D. (2016) · Power Systems Computation Conference · doi:10.1109/pscc.2016.7540931 · Cited by 6
Impact of Degraded Communication on Interdependent Power Systems: The Application of Grid Splitting
Tian, D.-A., & Sansavini, G. (2016) · Electronics · doi:10.3390/electronics5030049 · Cited by 6
“In view of operations closer to stability limits, the use of ICT is expected to turn the current grid into a “smart grid” [7], making it self-healing and increasing its efficiency, reliability, security and quality of service [8].”
BackgroundEnergy Transduction Optimization of a Wave Energy Converter by Evolutionary Algorithms
Capillo, A., Luzi, M., Pasc, M., Rizzi, A., & Mascioli, F. M. F. (2018) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2018.8489129 · Cited by 6
“The enhanced stability of the whole power grid and the energy optimization are among the advantages coming from the adoption of Smart Grids [8].”
InfluentialQuality Assessment of Smart Grid Data
Radhakrishnan, A., & Das, S. (2018) · National Power Systems Conference · doi:10.1109/npsc.2018.8771733 · Cited by 6
“Data quality improvement has become a necessity for better monitoring and control of SGs [19].”
BackgroundHolistic Control Approach for the Grid-Connected Converter of a Battery Energy Storage System
Nunez, C. A., Visairo-Cruz, N., Arellanes, A., Mora, D., & Segundo‐Ramírez, J. (2020) · IEEE Access · doi:10.1109/access.2020.3038149 · Cited by 6
“In [4]–[7], several applications for BESS can be found, and their scopes are explained.”
BackgroundPower Quality Issues Associated with Smart Grid: A Review
Verma, P. K., & Goswami, G. (2021) · International Conference on System Modeling & Advancement in Research Trends (SMART) · doi:10.1109/smart52563.2021.9676312 · Cited by 6
A Reliable Communication Framework and Its Use in Internet of Things (IoT)Preprint
Alam, T. (2020) · doi:10.36227/techrxiv.12657158 · Cited by 6
Tang, M., Krstić, M., & Poveda, J. I. (2025) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2025.3631559 · Cited by 5
“Such multitime-scale systems are common across a diverse array of engineering applications, including aerospace [1], chemical processing [2], smart grids [3], and biological and evolutionary systems [4], among others.”
Overview of Research Challenges towards Smart Grid Quality by Design
Gešvindr, D., Bühnová, B., & Rosecký, J. (2014) · Annals of Computer Science and Information Systems · doi:10.15439/2014f318 · Cited by 5
“The reliability engineering in the Smart Grid domain aims at incorporating autonomous control actions to enhance reliability by increasing resiliency against component failures and natural disasters, and by minimizing frequency and magnitude of power outages subject to regulatory policies, operating requirements, equi…”
BackgroundGong, L., Zhang, Y., Yang, M., Li, Y., Liu, F., & Yao, Q. (2021) · IEEE International Conference on Software Quality, Reliability and Security Companion (QRS-C) · doi:10.1109/qrs-c55045.2021.00026 · Cited by 5
Deep Reinforcement Learning Based Autonomous Control Approach for Power System Topology Optimization
Han, X., Yi, H., Chong, Z., Ma, S., & Mu, C. (2022) · Chinese Control Conference (CCC) · doi:10.23919/ccc55666.2022.9902073 · Cited by 5
“Nowadays with the construction of high-power ultra-high voltage AC/DC hybrid power grid, high proportion of renewable energy and intelligent electronic devices are widely connected to the power grid[1], and the power market has been deregulated [2].”
BackgroundMaximizing energy injections of distributed generation in rural areas
Muzi, F., & Pompili, M. (2015) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesgm.2015.7286175 · Cited by 5
“Another well-known drawback is the phenomenon of the so-called current flow inversion [4], due to an important generation increase, which is responsible for reverse power flows on the MV lines that can also go up the HV system.”
BackgroundEconomic energy distribution and consumption in a microgrid Part1: Cell level controller
Tahersima, F., Andersen, P., & Madsen, P. P. (2013) · The proceedings of the IEEE Conference on Control Applications/The proceedings of the ... IEEE Conference on Control Applications · doi:10.1109/cca.2013.6662776 · Cited by 5
“…to encourage individual units for example detached houses, residential or office buildings to consume electricity when energy surpluses in the grid by shifting their power demands; And use local energy resources or the stored energy when there is power congestion or deficit in the grid [3], [4].”
BackgroundUsing a Microgrid test bed to evaluate the strategies for seamless renewable energy integration
Liu, M., Ding, Z., Quilumba, F. L., Lee, W., & Wetz, D. A. (2014) · IEEE/IAS Industrial and Commercial Power Systems Technical Conference · doi:10.1109/icps.2014.6839171 · Cited by 5
On the efficiency-vs-security tradeoff in the smart grid
Abdallah, Y., Zheng, Z., Shroff, N. B., & Gamal, H. E. (2012) · IEEE Conference on Decision and Control (CDC) · doi:10.1109/cdc.2012.6425909 · Cited by 6
“I. INTRODUCTION Over the past few years, the smart grid has received considerable momentum, exemplified in several regulatory and policy initiatives, and research efforts (see for example [1], [2] and the references therein).”
BackgroundShabani, H., Ahmed, M. M., & Saeed, R. A. (2011) · Cited by 5
A low-cost GPRS based communication system for a smart transformer
Gehm, A. A. B., Quevedo, J. O., Martins, M. L. D. S., & Beltrame, R. C. (2014) · IEEE International Conference on Industry Applications · doi:10.1109/induscon.2014.7059451 · Cited by 5
Alkaabi, S. S., Zeineldin, H. H., Khadkikar, V., & Moursi, M. S. E. (2017) · IEEE Power & Energy Society Innovative Smart Grid Technologies Conference (ISGT) · doi:10.1109/isgt.2017.8085970 · Cited by 5
Farag, H. E. Z., Abdelaziz, M. M. A., & El-Saadany, E. F. (2013) · IEEE Power Engineering Society General Meeting · doi:10.1109/pesmg.2013.6672692 · Cited by 5
“The main goals of the smart grid paradigm are: 1) transform the power system from the centralized scheme to a deregulated structure, 2) facilitate the interaction between customers, network operators and power producers, and 3) increase the system reliability and efficiency [1-3].”
BackgroundBehaviour Evaluation of GOOSE Message Traffic between Power Substations: A POTT Scheme Case Study
Miranda, J. C., Netto, U. C., Coury, D. V., & Oleskovicz, M. (2013) · Journal of Control Automation and Electrical Systems · doi:10.1007/s40313-013-0087-1 · Cited by 5
“This is the core of the smart grids concept (IEEE 2011; Hassan and Radman 2010; Xin-wei and Qiang 2010; Moslehi and Kumar 2010).”
BackgroundConceptual data management and communication for smart distribution system
Jamian, J. J., Mustafa, M. W., Mokhlis, H., & Bahamdin, M. A. (2011) · IEEE Conference on Clean Energy and Technology (CEAT) · doi:10.1109/cet.2011.6041510 · Cited by 5
“requirements, a two way communication is needed [6][ 12 ].”
BackgroundOn massive MIMO and its applications to machine type communications and FBMC-based networks
Miranda, J. P., Farhang, A., Marchetti, N., de Figueiredo, F. A. P., Cardoso, F. A. C. M., & Figueiredo, F. L. (2015) · ICST Transactions on Ubiquitous Environments · doi:10.4108/ue.2.5.e3 · Cited by 5
“Reliability in smart grid and critical infrastructure monitoring, for instance, is often achievable only via dedicated landlines [8, 9].”
BackgroundAn auxiliary study of the smart grid deployment in India. Philosophy and key drivers
Beg, F. (2016) · International Journal of Smart Grid and Green Communications · doi:10.1504/ijsggc.2016.077288 · Cited by 5
“5% and 11% respectively in the year 2011–12 (Moslehi and Kumar, 2010).”
BackgroundInfluentialDistributed Generation Operation in Micro-Grid by using Smart Distribution Systems
Prakash, A. C., & Reddy, D. S. (2016) · Indian Journal of Science and Technology · doi:10.17485/ijst/2016/v9i35/97930 · Cited by 5
Reliability evaluation of BLDC drive in refrigeration systems
Kadwane, S. G., Kumbhare, J. M., Gawande, S. P., & Mohanta, D. K. (2016) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2016.7793538 · Cited by 5
“Reliability analysis of smart grid is also an important aspect which is introduced in [8].”
BackgroundAre the Current Smart Grid Concepts Likely to Offer a Complete Smart Grid Solution?
Ilo, A. (2017) · Smart Grid and Renewable Energy · doi:10.4236/sgre.2017.87017 · Cited by 5
Tian, D.-A., & Sansavini, G. (2018) · Proceedings of the Institution of Mechanical Engineers Part O Journal of Risk and Reliability · doi:10.1177/1748006x17736165 · Cited by 5
Demand Side Management in Microgrids
Gilda, K., Chaphekar, S. N., Dharme, A. A., & Talange, D. B. (2018) · International Conference on Emerging Trends and Innovations in Engineering and Technological Research (ICETIETR) · doi:10.1109/icetietr.2018.8529024 · Cited by 5
“DSM can be a good solution to gain control of loads with respect to the generation [8].”
BackgroundReliability Evaluation of ICT Used on Dynamic Line Rating for Power System Flexibility
Cruzat, C., & Kopsidas, K. (2019) · doi:10.1109/ptc.2019.8810609 · Cited by 5
Metadata
- Authors
- Moslehi, K., & Kumar, R.
- ORCID
- Moslehi, Khosrow
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2010-06
- Volume
- 1
- Issue
- 1
- Pages
- 57-64
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2109176395
- Cited by
- 932
- References
- 5
- Citations by year
- 2026: 11 · 2025: 19 · 2024: 31 · 2023: 37 · 2022: 51 · 2021: 51 · 2020: 69 · 2019: 69 · 2018: 69 · 2017: 63 · 2016: 74 · 2015: 81 · 2014: 97 · 2013: 86 · 2012: 70
- FWCI
- 52.71
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- IEEE Transactions on Smart Grid (publishedVersion)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid and Power Systems
- Physical Sciences › Engineering › Safety, Risk, Reliability and Quality › Power System Reliability and Maintenance
- Physical Sciences › Engineering › Control and Systems Engineering › Smart Grid Security and Resilience
- Keywords
- smart grid, power system reliability, renewable energy integration, demand response, energy storage, IT architecture, cybersecurity, information and communication technologies
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.