Modeling Load Redistribution Attacks in Power Systems
The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
State estimation is a key element in today's power systems for reliable system operation and control. State estimation collects information from a large number of meter measurements and analyzes it in a centralized manner at the control center. Existing state estimation approaches were traditionally assumed to be able to tolerate and detect random bad measurements. They were, however, recently shown to be vulnerable to intentional false data injection attacks. This paper fully develops the concept of load redistribution (LR) attacks, a special type of false data injection attacks, and analyzes their damage to power system operation in different time steps with different attacking resource limitations. Based on damaging effect analysis, we differentiate two attacking goals from the adversary's perspective, i.e., immediate attacking goal and delayed attacking goal. For the immediate attacking goal, this paper identifies the most damaging LR attack through a max-min attacker-defender model. Then, the criterion of determining effective protection strategies is explained. The effectiveness of the proposed model is tested on a 14-bus system. To the author's best knowledge, this is the first work of its kind, which quantitatively analyzes the damage of the false data injection attacks to power system operation and security. Our analysis hence provides an in-depth insight on effective attack prevention with limited protection resource budget.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Abur, A., & Expósito, A. G. (2004) · CRC Press eBooks · doi:10.1201/9780203913673 · Cited by 2,974
Market Operations in Electric Power Systems: Forecasting, Scheduling, and Risk Management
Shahidehpour, M., Yamin, H., & Li, Z. (2002) · Wiley eBooks · doi:10.1002/047122412x · Cited by 1,616
Self-citationFalse data injection attacks against state estimation in electric power grids
Liu, Y., Ning, P., & Reiter, M. K. (2009) · Proceedings of the 16th ACM conference on Computer and communications security · doi:10.1145/1653662.1653666 · Cited by 1,285
A Representation and Economic Interpretation of a Two-Level Programming Problem
Fortuny‐Amat, J., & McCarl, B. A. (1981) · Journal of the Operational Research Society · doi:10.1057/jors.1981.156 · Cited by 1,174
State Estimation in Electric Power Systems
Monticelli, A. (1999) · Springer eBooks · doi:10.1007/978-1-4615-4999-4 · Cited by 713
State Estimation in Electric Power Systems: A Generalized Approach
Monticelli, A. (1999) · Cited by 682
Analysis of Electric Grid Security Under Terrorist Threat
Salmeron, J., Wood, K., & Baldick, R. (2004) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2004.825888 · Cited by 562
On Security Indices for State Estimators in Power Networks
Sandberg, H., Teixeira, A. M. H., & Johansson, K. H. (2010) · Cited by 319
Worst-Case Interdiction Analysis of Large-Scale Electric Power Grids
Salmeron, J., Wood, K., & Baldick, R. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2008.2004825 · Cited by 260
On the Solution of the Bilevel Programming Formulation of the Terrorist Threat Problem
Arroyo, J. M., & Galiana, F. D. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.846198 · Cited by 239
A Mixed-Integer LP Procedure for the Analysis of Electric Grid Security Under Disruptive Threat
Motto, A. L., Arroyo, J. M., & Galiana, F. D. (2005) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2005.851942 · Cited by 214
Limiting false data attacks on power system state estimation
Kosut, O., Jia, L., Thomas, R. J., & Tong, L. (2010) · Conference on Information Sciences and Systems · doi:10.1109/ciss.2010.5464816 · Cited by 167
Strategic Generation Capacity Expansion Planning With Incomplete Information
Wang, J., Shahidehpour, M., Li, Z., & Botterud, A. (2009) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2009.2017435 · Cited by 129
Self-citation
Cited by
Smart Grid — The New and Improved Power Grid: A Survey
Fang, X., Misra, S., Xue, G., & Yang, D. (2012) · IEEE Communications Surveys & Tutorials · doi:10.1109/surv.2011.101911.00087 · Cited by 3,405
The 2015 Ukraine Blackout: Implications for False Data Injection Attacks
Liang, G., Weller, S. R., Zhao, J., Luo, F., & Dong, Z. Y. (2017) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2016.2631891 · Cited by 1,248
Cyber security in the Smart Grid: Survey and challenges
Wang, W., & Lu, Z. (2013) · Computer Networks · doi:10.1016/j.comnet.2012.12.017 · Cited by 1,123
A Review of False Data Injection Attacks Against Modern Power Systems
Liang, G., Zhao, J., Luo, F., Weller, S. R., & Dong, Z. Y. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2495133 · Cited by 1,028
EPPA: An Efficient and Privacy-Preserving Aggregation Scheme for Secure Smart Grid Communications
Lu, R., Liang, X., Li, X., Lin, X., & Shen, X. (2012) · IEEE Transactions on Parallel and Distributed Systems · doi:10.1109/tpds.2012.86 · Cited by 772
Metadata
- Authors
- Yuan, Y., Li, Z., & Ren, K.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2011-06
- Volume
- 2
- Issue
- 2
- Pages
- 382-390
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2122559297
- Cited by
- 545
- References
- 13
- FWCI
- 27.58
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.