The DOI matches its Crossref record.
Security Framework for Wireless Communications in Smart Distribution Grid
Abstract
Communication networks play a critical role in smart grid, as the intelligence of smart grid is built based on information exchange across the power grid. In power transmission segments of smart grid, wired communications are usually adopted to ensure robustness of the backbone power network. In contrast, for a power distribution grid, wireless communications provide many benefits such as low cost high speed links, easy setup of connections among different devices/appliances, and so on. Connecting power equipment, devices, and appliances through wireless networks is indispensable for a smart distribution grid (SDG). However, wireless communications are usually more vulnerable to security attacks than wired ones. Developing appropriate wireless communication architecture and its security measures is extremely important for an SDG. Thus, these two problems are investigated in this paper. Firstly, a wireless communication architecture is proposed for an SDG based on wireless mesh networks (WMNs). The security framework under this communication architecture is then analyzed. More specifically, potential security attacks and possible counter-attack measures are studied. Within the security framework, a new intrusion detection and response scheme, called smart tracking firewall, is developed to meet the special requirements of SDG wireless communications. Performance results show that the smart tracking firewall can quickly detect and respond to security attacks and is thus suitable for real-time operation of an SDG.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Manandhar, K., Cao, X., Hu, F., & Liu, Y. (2014) · IEEE Transactions on Control of Network Systems · doi:10.1109/tcns.2014.2357531 · Cited by 786
Secure Anonymous Key Distribution Scheme for Smart Grid
Tsai, J.-L., & Lo, N.-W. (2015) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2015.2440658 · Cited by 306
Privacy-Enhanced Data Aggregation Scheme Against Internal Attackers in Smart Grid
Fan, C.-I., Huang, S.-Y., & Lai, Y.-L. (2014) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2013.2277938 · Cited by 256
Smart Grid Security: Threats, Vulnerabilities and Solutions
Aloul, F., Al-Ali, A. R., Al-Dalky, R., Al-Mardini, M., & El-Hajj, W. (2012) · International Journal of Smart Grid and Clean Energy · doi:10.12720/sgce.1.1.1-6 · Cited by 197
Behavior-Rule Based Intrusion Detection Systems for Safety Critical Smart Grid Applications
Mitchell, R., & Chen, I.-R. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2258948 · Cited by 184
Metadata
- Authors
- Wang, X., & Yi, P.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2011-12
- Volume
- 2
- Issue
- 4
- Pages
- 809-818
- ISSN
- 1949-3053 (ISSN-L)
- OpenAlex
- W2119856652
- Cited by
- 187
- References
- 0
- FWCI
- 28.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Security Framework for Wireless Communications in Smart Distribution Grid. https://app.cochat.ai/papers/10.1109/tsg.2011.2167354
- The paper
- Wang, X., & Yi, P. (2011). Security Framework for Wireless Communications in Smart Distribution Grid. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2011.2167354
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.