Investigation of Domestic Load Control to Provide Primary Frequency Response Using Smart Meters

Samarakoon, Kamalanath, Ekanayake, Janaka, Jenkins, Nick · 2012 · IEEE Transactions on Smart Grid

The DOI matches its Crossref record; 7 of the 8 references it cites were found in a registry or an index.

Abstract

The ability of smart meters to control domestic demand during system emergencies was investigated. Direct load control through the smart meters is unlikely to be able to provide primary frequency response because of communication delays. An alternative load control scheme that used a local frequency measurement from the smart meters was investigated. An experimental rig was developed, using commercially available components, to test and demonstrate the load control scheme. The amount of load to be controlled to limit the frequency drop of the Great Britain system to a set of minimum allowable frequencies was found using a simulation program. Operating speeds and the limitations of the components of the load controller in providing primary response are discussed. It is shown that if smart meters are to play any role in primary response then the speed at which the system frequency is measured must be increased very considerably (from around 3 s to 200 ms). This has important implications as the U.K. is now finalizing the specification for more than 20 million smart electricity meters that will be installed by 2020.

Overview

Integrity signals

Registry

Crossref · 10.1109/tsg.2011.2173219

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 7 references

Research works printed but not linked: 15

  1. 2011, Smart Metering implementation programme Prospectus
  2. 2007, Assessment of Demand Response and Advanced Metering
  3. 0, Itron and Comverge partner for demand response technology
  4. 2005, IEEE Standard Communication Delivery Time Performance Requirements for Electric Power Substation Automation
  5. 2010, SEESGEN-ICT Project document SEESGEN—ICT D2.2, Report on ICT Requirements Offers and Needs for Managing Smart Grids With DER
  6. 0, Microsoft Visual Basic
  7. 0, National Grid plc, Procurement Guidelines Report
  8. 0, Future Balancing Services Requirements Reserve
  9. 0, National Grid Monthly Balancing Services Summary
  10. 2008, The potential for dynamic demand
  11. 2010, Grid Responsive Control Device
  12. 0, ConsoliTech
  13. bopp, 2006, Technical and commercial integration of distributed and renewable energy sources into existing electricity networks
  14. 0, ControlThink
  15. 0, National Grid Demand Data

Cited by

Items 201–201 of 201

Metadata

Authors
Samarakoon, K., Ekanayake, J., & Jenkins, N.
Affiliations
Cardiff University (GB)
Venue
IEEE Transactions on Smart Grid
Published
2012-03
Volume
3
Issue
1
Pages
282-292
ISSN
  • 1949-3053 (ISSN-L)
  • 1949-3061
OpenAlex
W2068929682
Cited by
200
References
8
Citations by year
2026: 3 · 2025: 2 · 2024: 7 · 2023: 11 · 2022: 17 · 2021: 14 · 2020: 23 · 2019: 18 · 2018: 15 · 2017: 18 · 2016: 25 · 2015: 10 · 2014: 19 · 2013: 13 · 2012: 5
FWCI
8.29
Type
journal article
Language
en
Open access
closed
Locations
  • IEEE Transactions on Smart Grid (publishedVersion)
  • ORCA Online Research @Cardiff (Cardiff University) (submittedVersion)
Funders
Engineering and Physical Sciences Research Council (EP/E017444/2, EP/E036503/1)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Smart Grid Energy Management
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Frequency Control in Power Systems
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
Keywords
primary frequency response, smart meters, direct load control, communication delay, frequency drop, Great Britain electricity system

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.