The DOI matches its Crossref record.
Coordinated Control of Distributed Energy Storage System With Tap Changer Transformers for Voltage Rise Mitigation Under High Photovoltaic Penetration
Abstract
This paper proposes a coordinated control of distributed energy storage system (ESS) with traditional voltage regulators including the on-load tap changer transformers (OLTC) and step voltage regulators (SVR) to solve the voltage rise problem caused by the high photovoltaic (PV) penetration in the low-voltage distribution network. The main objective of this coordinated control is to relieve the tap changer transformer operation stress, shave the distribution network peak load and decrease the transmission and distribution resistive power losses under high solar power penetration. The proposed control method limits the energy storage depth of discharge in order to meet a more than ten-year cycle life. A benchmark distribution network model was developed in the Real Time Digital Simulator (RTDS) and the simulation results from the studied cases verified the proposed coordinated control strategy. The experimental implementation of proposed control algorithms were developed based on a power hardware-in-the-loop (PHIL) test bed with a 22 kWh ESS, a smart meter, Labview controller, and RTDS. The experimental results were consistent with those obtained from simulation study.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Haque, M. M., & Wolfs, P. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.04.025 · Cited by 331
Alam, M. J. E., Muttaqi, K. M., & Sutanto, D. (2013) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2013.2259269 · Cited by 330
Methods and strategies for overvoltage prevention in low voltage distribution systems with PV
Hashemi, S., & Østergaard, J. (2017) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2016.0277 · Cited by 212
Review on the PV Hosting Capacity in Distribution Networks
Fatima, S., Püvi, V., & Lehtonen, M. (2020) · Energies · doi:10.3390/en13184756 · Cited by 137
Lee, H.-S., & Yun, J.-J. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2018.2860059 · Cited by 123
Metadata
- Authors
- Liu, X., Aichhorn, A., Liu, L., & Li, H.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2012-06
- Volume
- 3
- Issue
- 2
- Pages
- 897-906
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W1998572623
- Cited by
- 486
- References
- 0
- FWCI
- 22.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coordinated Control of Distributed Energy Storage System With Tap Changer Transformers for Voltage Rise Mitigation Under High Photovoltaic Penetration. https://app.cochat.ai/papers/10.1109/tsg.2011.2177501
- The paper
- Liu, X., Aichhorn, A., Liu, L., & Li, H. (2012). Coordinated Control of Distributed Energy Storage System With Tap Changer Transformers for Voltage Rise Mitigation Under High Photovoltaic Penetration. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2011.2177501
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.