The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Laboratory-Based Smart Power System, Part I: Design and System Development
Abstract
This paper presents the design and development of a hardware-based laboratory smart grid test-bed. This system is developed at the Energy Systems Research Laboratory, Florida International University. The hardware/software based system includes implementation of control strategies for generating stations, and power transfer to programmable loads in a laboratory scale of up to 35 kilowatts in ac power and 36 kW in renewable sources and energy storages. Appropriate software was developed to monitor all system parameters as well as operate and control the various interconnected components in varying connectivity architectures. The interconnection of alternate energy such as wind emulators, PV arrays, and fuel cell emulators are implemented, studied and integrated into this system. Educational experiences were drawn during the design and system development of this laboratory-based smart grid. The real-time operation and analysis capability provides a platform for investigation of many challenging aspects of a real smart power system. The design, development, and hardware setup of this laboratory is presented here in Part I of this paper. This includes component development, hardware implementation, and control and communication capabilities. Part II of the paper presents the implementation of the monitoring, control, and protection system of the whole setup with detailed experimental and simulation results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A reliability perspective of the smart grid
Moslehi, K., & Kumar, R. (2010) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2010.2046346 · Cited by 932
Cited by
DC microgrids and distribution systems: An overview
Elsayed, A. T., Mohamed, A. A., & Mohammed, O. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.10.017 · Cited by 590
Self-citationEnergy Management and Control System for Laboratory Scale Microgrid Based Wind-PV-Battery
Merabet, A., Tawfique Ahmed, K., Ibrahim, H., Beguenane, R., & Ghias, A. M. Y. M. (2017) · IEEE Transactions on Sustainable Energy · doi:10.1109/tste.2016.2587828 · Cited by 433
A Survey on Smart Grid Cyber-Physical System Testbeds
Cintuglu, M. H., Mohammed, O. A., Akkaya, K., & Uluagac, A. S. (2017) · IEEE Communications Surveys & Tutorials · doi:10.1109/comst.2016.2627399 · Cited by 421
Self-citationSynchrophasor Measurement Technology in Power Systems: Panorama and State-of-the-Art
Aminifar, F., Fotuhi-Firuzabad, M., Safdarian, A., Davoudi, A., & Shahidehpour, M. (2014) · IEEE Access · doi:10.1109/access.2015.2389659 · Cited by 261
Metadata
- Authors
- Salehi, V., Mohamed, A., Mazloomzadeh, A., & Mohammed, O. A.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2012-09
- Volume
- 3
- Issue
- 3
- Pages
- 1394-1404
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W1972547212
- Cited by
- 175
- References
- 1
- FWCI
- 26.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Laboratory-Based Smart Power System, Part I: Design and System Development. https://app.cochat.ai/papers/10.1109/tsg.2012.2194518
- The paper
- Salehi, V., Mohamed, A., Mazloomzadeh, A., & Mohammed, O. A. (2012). Laboratory-Based Smart Power System, Part I: Design and System Development. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2012.2194518
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.