The DOI matches its Crossref record.
Optimizing the Roles of Unit and Non-unit Protection Methods Within DC Microgrids
Abstract
The characteristic behavior of physically compact, multiterminal dc networks under electrical fault conditions can produce demanding protection requirements. This represents a significant barrier to more widespread adoption of dc power distribution for microgrid applications. Protection schemes have been proposed within literature for such networks based around the use of non-unit protection methods. This paper shows however that there are severe limitations to the effectiveness of such schemes when employed for more complex microgrid network architectures. Even current differential schemes, which offer a more effective, though costly, protection solution, must be carefully designed to meet the design requirements resulting from the unique fault characteristics of dc microgrids. This paper presents a detailed analysis of dc microgrid behavior under fault conditions, illustrating the challenging protection requirements and demonstrating the shortcomings of non-unit approaches for these applications. Whilst the performance requirements for the effective operation of differential schemes in dc microgrids are shown to be stringent, the authors show how these may be met using COTS technologies. The culmination of this work is the proposal of a flexible protection scheme design framework for dc microgrid applications which enables the required levels of fault discrimination to be achieved whilst minimizing the associated installation costs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
DC microgrids and distribution systems: An overview
Elsayed, A. T., Mohamed, A. A., & Mohammed, O. A. (2015) · Electric Power Systems Research · doi:10.1016/j.epsr.2014.10.017 · Cited by 590
AC and DC technology in microgrids: A review
Planas, E., Andreu, J., Gárate, J. I., Martínez de Alegría, I., & Ibarra, E. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2014.11.067 · Cited by 500
DC Microgrid Protection: A Comprehensive Review
Beheshtaein, S., Cuzner, R. M., Forouzesh, M., Savaghebi, M., & Guerrero, J. M. (2024) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2019.2904588 · Cited by 365
Metadata
- Authors
- Fletcher, S. D. A., Norman, P. J., Galloway, S. J., Crolla, P., & Burt, G. M.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2012-12
- Volume
- 3
- Issue
- 4
- Pages
- 2079-2087
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2080326549
- Cited by
- 214
- References
- 0
- FWCI
- 12.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optimizing the Roles of Unit and Non-unit Protection Methods Within DC Microgrids. https://app.cochat.ai/papers/10.1109/tsg.2012.2198499
- The paper
- Fletcher, S. D. A., Norman, P. J., Galloway, S. J., Crolla, P., & Burt, G. M. (2012). Optimizing the Roles of Unit and Non-unit Protection Methods Within DC Microgrids. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2012.2198499
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.