A Smart Domestic Hot Water Buffer
The DOI matches its Crossref record.
Abstract
Demand response is seen as a key technology to help the introduction of large volumes of intermittent renewable energy and to help mitigate the effects of the increasing load on the electricity distribution grid. A large and diverse number of control mechanisms are proposed for demand response, while multiple industrial companies are designing their own proprietary solutions. This situation demands for standardized and generalized interfaces for smart devices, i.e., interfaces based on as few indicators as possible that reflect the flexibility state, while hiding all implementation details and specifics of the device. Electric domestic hot water buffers are devices that inherently contain a lot of flexibility, i.e., the charging can be shifted without impact on the comfort of the user. This article presents four key indicators for domestic hot water buffers that meet above requirements: P, the rated power,Emax, the energy required to fully charge the buffer, SoC, the state of charge, andEmin, the energy required before the SoC increases. The correct behavior of these key indicators has been validated by means of simulations and measurements on a lab prototype. The integration of the smart buffer into a time of use demand response system is demonstrated with a test setup and measurement results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
D’hulst, R., Labeeuw, W., Beusen, B., Claessens, S., Deconinck, G., & Vanthournout, K. (2015) · Applied Energy · doi:10.1016/j.apenergy.2015.05.101 · Cited by 387
Self-citationResidential Demand Response of Thermostatically Controlled Loads Using Batch Reinforcement Learning
Ruelens, F., Claessens, B. J., Vandael, S., De Schutter, B., Babuska, R., & Belmans, R. (2017) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2517211 · Cited by 333
Dynamic Load Altering Attacks Against Power System Stability: Attack Models and Protection Schemes
Amini, S., Pasqualetti, F., & Mohsenian-Rad, H. (2018) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2016.2622686 · Cited by 245
“, LG Thinq, [34], air conditioners [13], water heaters [35], irrigation pumps [36], electric vehicles [37], and computation equipment [38].”
BackgroundBenefits of Demand Response on Operation of Distribution Networks: A Case Study
Safdarian, A., Fotuhi-Firuzabad, M., & Lehtonen, M. (2016) · IEEE Systems Journal · doi:10.1109/jsyst.2013.2297792 · Cited by 162
Kazmi, H., Mehmood, F., Lodeweyckx, S., & Driesen, J. (2018) · Energy · doi:10.1016/j.energy.2017.12.019 · Cited by 109
Metadata
- Authors
- Vanthournout, K., D'hulst, R., Geysen, D., & Jacobs, G.
- Venue
- IEEE Transactions on Smart Grid
- Published
- 2012-12
- Volume
- 3
- Issue
- 4
- Pages
- 2121-2127
- ISSN
- 1949-3053 (ISSN-L)
- 1949-3061
- OpenAlex
- W2022935688
- Cited by
- 94
- References
- 0
- FWCI
- 7.53
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Smart Domestic Hot Water Buffer. https://app.cochat.ai/papers/10.1109/tsg.2012.2205591
- The paper
- Vanthournout, K., D'hulst, R., Geysen, D., & Jacobs, G. (2012). A Smart Domestic Hot Water Buffer. IEEE Transactions on Smart Grid. https://doi.org/10.1109/tsg.2012.2205591
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.